Appendix. Configuration Downlink Command
Port
204
Appx. 1 Payload
Bytes
0
1~4
Field
Cmd
Config
Cmd
Command
1 byte
Bit [7:0]
0x00 – Set keep-alive interval.
default value : => 300 sec
value range : 15~65535
0x01 – Set sensor detection interval.
default value : 300 (sec)
value range : 0 or 15~65535
0x02 – Set sensor’s
decibel
threshold to trigger events.
default value : 80 (dBA)
value range: 40~100
Note:
The keep-alive interval should be greater than or equal to the
detection interval.
Config
Configuration
0~2 bytes
See the table as follows:
Cmd
Command Description
Config Length
0x00
Get Sensor Configuration
(Only for unconfirmed downlink)
0 bytes
0x00
Set keep-alive interval
*Note: little-endian format.
2 bytes
0x01
Set sensor detection interval
*Note: little-endian format.
2 bytes
0x02
Set sensor’s
decibel
threshold to trigger event
1 byte
© 2019 Browan Communications Inc. All rights reserved.
13