Introduction

Congratulations on your purchase of the ExStik

®

 DO600 

dissolved oxygen / temperature meter which simultane-

ously displays dissolved oxygen and temperature. Units 

of measure are % saturation, mg/l or ppm for dissolved 

oxygen, and °C or °F for temperature. Advanced features 

include Data Hold, 25 points memory, auto power off, 

automatic temperature compensation, salinity and altitude 

compensation. This meter is shipped fully tested and cali-

brated and, with proper use, will provide years of reliable 

service.

Meter Description

Front Panel Description

1.  Battery compartment cover

2.   LCD Display

3.   MODE/HOLD button

4.   CAL/RECALL button

5.   ON/OFF button

6.   Electrode Retaining Collar

7.   Dissolved Oxygen Sensor

8.   Bonded Membrane Cap assembly

9.   Membrane & Cathode
(Note: The Electrode storage cap is not shown)

Electrode Bottom View

1.  Membrane

2.  Cathode

LCD Display

1.   Bar graph display

2.   Measurement units

3.   Main display

4.   Low Battery indicator

5.   Temperature display

6.   Reading hold indicator

DO600-EU-NL-V7.0-8/10 

2

Dissolved Oxygen

DO600

II

RECALL

1

2

3

4
5

6

7

8

9

Inleiding 

Gefeliciteerd met de aankoop van de ExStik

®

 DO600, de opgeloste 

zuurstofmeter/temperatuurmeter die tegelijk de opgeloste zuurstof en de temperatuur 

weergeeft. De meeteenheden zijn % verzadiging, mg/l of ppm voor de opgeloste 

zuurstof en °C of °F voor de temperatuur. De gevorderde kenmerken omvatten Data 

Hold (databewaring), een geheugen van 25 punten, automatische uitschakeling, 

automatische temperatuurcompensatie, zoutgehalte en hoogtecompensatie. Als u deze 

meter voorzichtig gebruikt en onderhoudt, zal hij u jarenlang trouwe diensten bewijzen.  

Beschrijving van de meter 

Beschrijving frontpaneel 

1.  Deksel batterijvak 
2. LCD-display 
3.

MODE/HOLD

-toets 

4.

CAL/RECALL

-toets  

5.

AAN/UIT-

toets 

6. Elektrodekraag 
7.  Opgeloste zuurstofsensor 
8.  Borgkapconstructie voor het membraan  
9.  Membraan & kathode 

(Nota: De elektrodekap is niet afgebeeld)  

Benedenaanzicht elektrode 

1. Membraan 

2. Kathode 

LCD-display 

1.  Display balkgrafiek 
2. Meeteenheden 
3. Hoofdscherm 
4.  Indicator lage batterijstand 
5. Temperatuurdisplay 
6.  Aflezing hold-indicator 

1

2

Dissolved Oxygen

DO600

II

RECALL

Gebruiksaanwijzing

ExStik

®

 DO600 

Opgeloste zuurstofmeter 

1

2

3

4

5

6

7

8

9

DO600-EU-NL-V7.0-8/10 

2

Dissolved Oxygen

DO600

II

RECALL

1

2

3

4
5

6

7

8

9

Inleiding 

Gefeliciteerd met de aankoop van de ExStik

®

 DO600, de opgeloste 

zuurstofmeter/temperatuurmeter die tegelijk de opgeloste zuurstof en de temperatuur 

weergeeft. De meeteenheden zijn % verzadiging, mg/l of ppm voor de opgeloste 

zuurstof en °C of °F voor de temperatuur. De gevorderde kenmerken omvatten Data 

Hold (databewaring), een geheugen van 25 punten, automatische uitschakeling, 

automatische temperatuurcompensatie, zoutgehalte en hoogtecompensatie. Als u deze 

meter voorzichtig gebruikt en onderhoudt, zal hij u jarenlang trouwe diensten bewijzen.  

Beschrijving van de meter 

Beschrijving frontpaneel 

1.  Deksel batterijvak 
2. LCD-display 
3.

MODE/HOLD

-toets 

4.

CAL/RECALL

-toets  

5.

AAN/UIT-

toets 

6. Elektrodekraag 
7.  Opgeloste zuurstofsensor 
8.  Borgkapconstructie voor het membraan  
9.  Membraan & kathode 

(Nota: De elektrodekap is niet afgebeeld)  

Benedenaanzicht elektrode 

1. Membraan 

2. Kathode 

LCD-display 

1.  Display balkgrafiek 
2. Meeteenheden 
3. Hoofdscherm 
4.  Indicator lage batterijstand 
5. Temperatuurdisplay 
6.  Aflezing hold-indicator 

1

2

Dissolved Oxygen Meter DO-600

 

Manual

Summary of Contents for Vinoferm DO-600

Page 1: ...eling automatische temperatuurcompensatie zoutgehalte en hoogtecompensatie Als u deze meter voorzichtig gebruikt en onderhoudt zal hij u jarenlang trouwe diensten bewijzen Beschrijving van de meter Beschrijving frontpaneel 1 Deksel batterijvak 2 LCD display 3 MODE HOLD toets 4 CAL RECALL toets 5 AAN UIT toets 6 Elektrodekraag 7 Opgeloste zuurstofsensor 8 Borgkapconstructie voor het membraan 9 Memb...

Page 2: ...was last turned OFF will remain on the display 3 If this is the first time the meter is powered up wait ap prox 3 minutes for the probe to polarize please disable auto power off Instructions for disabling auto power off are provided in a later section For more details please read the Startup Polarization Period paragraph earlier in this manual before continuing 4 Select the desired units of measur...

Page 3: ...es 20 000ft above sea level 4 Momentarily press the CAL RECALL button to save the compensation setting and return to the normal mea surement mode Auto Power OFF Feature The auto power off feature automatically shuts the meter off 10 minutes after the most recent button press To disable this feature refer to the Disable Auto Power OFF section Disable Auto Power OFF Feature With the unit ON momentar...

Page 4: ...it disconnects 3 To attach an electrode align the positioning keys on the electrode and the main body housing and then care fully push the electrode into the meter socket until it is fully seated 4 Tighten the electrode retaining collar firmly enough to seal the electrode with the meter DO Bonded Membrane Cap replacement Important Note Do not touch the membrane as skin oils will interfere with the...

Page 5: ...ne Bonded membrane cap with threaded fitting Operating Temp Range 0 to 50 C 32 to 122 F ATC Range 0 to 50 C 32 to 122 F Salinity Compensation 0 to 50 ppt in 1 ppt part per thousand increments Altitude compensation 0 to 20 000 ft in 1000 ft increments Measurement Storage 25 tagged numbered data sets with recall Battery Power Four 4 CR2032 button batteries Low Battery Indication BAT appears on the L...

Page 6: ...is depleted Replace electrolyte and membrane cap assembly Readings drift down Insufficient stirring the probe consumes oxygen at the measuring surface requiring constant sample movement across membrane Move probe in sample or stir sample Slow Response Dirty or damaged membrane Replace electrolyte and membrane cap Electrode cannot be calibrated Depleted electrolyte Dirty or damaged membrane Replace...

Page 7: ...nity Compensation On Any Press and release the CAL RECALL button twice momentary in succession Displays SAL Changing Salinity Compensation On SAL Momentary press of the MODE HOLD button each button press increases the ratio by 1 ppt part per thousand the value cycles from 0 to 50 Exit Salinity Compensation On SAL Press and release CAL RECALL button for 2 seconds to enter Altitude Compensation Or P...

Page 8: ...ELF CAL lights Override Autopower Off On Any Press CAL RECALL button momentary then simultaneously press and hold the MODE HOLD and ON OFF buttons for for 2 seconds Default Reset Off n a off mode Simultaneously press ON OFF CAL RECALL and MODE HOLD momentarily dFLt will be displayed Re order and Accessory Information Part Number Description DO600 ExStik II Dissolved Oxygen Meter DO605 Replacement ...

Reviews: