Power
supply
lamp.
Fan switch.
3 position
fan speed switch.
Digital
thermostat.
Cooling switch
Control panel:
Lamp fascia panel:
Cooling mode.
Defrost mode
Low pressure warning
High pressure warning
Cooling mode: This lamp will be illuminated during normal cooling when the compressor is running.
Defrost mode: This lamp will be illuminated during a defrost cycle when the external heat exchanger
fan will be switched off. The appliance will start in defrost mode before cooling commences.
Low pressure warning: This lamp will be illuminated if there is a loss of refrigerant gas. The machine should
not be operated if this lamp activates. This will automatically shut down the compressor.
High pressure warning: This lamp will be illuminated when the regrigeration system pressure is too high.
(see fault finding). This will automatically shut down the compressor.