1: Regularly check the fluid level in the water tank and top up if necessary.
2: Check and clean the evaporator and external heat exchanger coils. Build up of dust
and dirt can severly effect the performance of the machine. Clean with compressed air.
3: Regularly inspect the mains cable and plug for signs of damage or wear. Do not operate
the machine with a damaged mains cable.
4: Check that the castors are running freely and that the breaking mechanisms are working
correctly.
5: Inspect the connection hose assembly for signs of wear or damage. Replace if necessary.
Troubleshooting guide:
Routine checks: