WARNINGS

These instructions should be read by:

The specifying engineer.

The installation engineer.

The user.

The service engineer.

Failure to follow  these instructions may result in risk of

         personal injury or damage to the equipment.

Damage due to a failure to follow these instructions will 

         invalidate the warranty.

The appliance must be serviced by qualified engineers

         in compliance with local regulations.

The appliance must be switched off and disconnected from

         the power supply before any work is carried out.

There are no user controls inside the appliance casing.

Do not place anything on top of the appliance.

An air gap of at least 300mm should be allowed at the front 

         and rear of the unit to ensure a clear airflow. 

Do not disconnect the appliance from  the supply under load.

For internal use only. Do not use out of doors.

Extension cables should be correctly rated for the load,fully

         unwound and never run through water or over sharp edges.

Always transport and store in an upright position.

Maximum operating temperature 35 C.

Minimum operating temperature 21 C.

Specifications:

The MCe6.0 is a Mono-block portable air conditioning unit.

It is connected to  a 13 Amp. 230Vac. 50Hz power supply and comes fitted with a fused 

uk moulded plug.
It is recommended that the supply to the machine should be protected by a 30mA RCD

SHEET 3 OF 13

Summary of Contents for MCe 6.0-21

Page 1: ...MCe 6 0 21 PORTABLE AIR CONDITIONER PRODUCT MANUAL MCe 6 0 21 SHEET 1 OF 13 ...

Page 2: ...rtant information P3 4 Technical specification P4 Set up and operation P5 6 Setting the digital thermostat P7 Control diagrams P8 Maintenance P9 10 Spare parts P11 12 Wiring diagrams P13 TABLE OF CONTENTS SHEET 2 OF 13 ...

Page 3: ...o not place anything on top of the appliance An air gap of at least 300mm should be allowed at the front and rear of the unit to ensure a clear airflow Do not disconnect the appliance from the supply under load For internal use only Do not use out of doors Extension cables should be correctly rated for the load fully unwound and never run through water or over sharp edges Always transport and stor...

Page 4: ...size for safe operation WARNING Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour SHEET 4 ...

Page 5: ...pplied loose The rear exhaust spigot must be fitted before use Tools required N02 PZ screwdriver 1 Remove the 4 x M5 fixings with star washers at the rear of the machine 2 Use these fixings to secure the exhaust spigot in place Pinch tight Ensure the exhaust spigot is correctly orientated Ensure the star washers are refitted Exhaust spigot fitted SHEET 5 OF 13 ...

Page 6: ...mperature is below 21 C The compressor is fitted with a start delay timer and will not run for 3 minutes from activation of the cooling switch This device is designed to protect the compressor from repeated start stop cycles Set the digital thermostat to the desired temperature This is the set point During normal running the digital thermostat read out shows the ambient temperature of the room See...

Page 7: ...oom temperature How to see the set point Defrost key Not used Set key Up down keys Power key Not used The appliance comes factory set at 21 C Push the SET key for more than 2 seconds to change the set point value The value of the set point will be displayed and the C LED starts blinking To change the set point value push the up or down arrows within 10 seconds The minimum set point is 21 C To memo...

Page 8: ...Water drain tank Locking castors Discharge hoses Exhaust spigot Tank full lamp Fans on rocker switch Cooling on rocker switch Digital controller Control panel Operation and controls SHEET 8 OF 13 ...

Page 9: ... available to hand Either Co2 or dry powder g All possible ignition sources should be kept sufficiently far away from the work area h Adequate ventilation shall be provided when breaking into the refrigeration system The ventilation should safely disperse any released refrigerant to the external atmosphere i When replacing electrical components only spare parts specified by the manufacturer shall ...

Page 10: ...nk drain mechanism is operating correctly and the drain hose is present and in good condition 3 Regularly inspect the mains cable and plug for signs of damage or wear Do not operate the machine with a damaged mains cable 4 Check that the castors are running freely and that the breaking mechanisms are working correctly Troubleshooting guide SHOULD YOU CONTINUE TO EXPERIENCE PROBLEMS PLEASE CONTACT ...

Page 11: ...27 28 1 2 3 4 5 6 7 8 9 11 13 14 15 16 18 19 20 21 24 25 26 35 23 34 32 33 29 30 31 17 Exploded view 10 12 SHEET 11 OF 13 ...

Page 12: ...Spare Parts SHEET 12 OF 13 ...

Page 13: ...MCe 6 0 21 Wiring diagram SHEET 13 OF 13 ...

Reviews: