![Brother TD-2020 Service Manual Download Page 84](http://html.mh-extra.com/html/brother/td-2020/td-2020_service-manual_2819644084.webp)
1 - 9
1.2.5 Read MAC Address
Acquires Wired LAN MAC address retained in EEPROM.
(1)
This inspection starts automatically when the previous inspection is completed. When
operating this inspection again, check that the "Check Mac address" field is highlighted in
yellow, then press the [Run] button.
(2)
Wired LAN MAC address appears in the "Mac address" field on the top of the window.
MAC address also appears in the "Results" field with a message confirming success.
Figure 9. MAC address check result
Inspection errors
• Can not connect.
The following error occurs when the machine is not connected with PC. Check that the
machine is connected to the PC properly and the machine is turned ON.
Figure 10. Can not connect.
• The mac address vendor code error.
The error shown below occurs when the MAC address has not been written in the EEPROM
of the machine.
Figure 11. The mac address vendor code error.
Model
Inspection
TD-2000
Invalid
TD-2100N
Valid