8. ELECTRICAL MECHANISM
197
RH-9820
8. ELECTRICAL MECHANISM
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the cover of the control box. Touching areas where high voltages are present can result in severe
injury.
8-1. Precautions while carrying out adjustments
Electric shocks
High voltages can remain in large-capacity capacitors for up to 5 minutes in some circumstances, even when the power has
been turned off. Accordingly, wait at least 5 minutes after turning off the power before carrying out the following operations.
•
Opening and closing the control box
•
Replacing
fuses
•
Inserting and disconnecting connectors
•
Measuring resistance values
•
Any other tasks that may involve touching components inside the control box
Some inspection items require the control box to be open when the power is turned on and voltages are measured.
At such times, be extremely careful never to touch anywhere other than the specified locations. In addition, note that high
voltages may remain for up to 5 minutes after the power is turned off.
Injury
Be careful not to touch metallic objects such as the heat sink and cover when connecting and disconnecting connectors and
making measurements.
Be sure to note the following cautions when opening the control box to carry out inspections and adjustments.
Summary of Contents for RH-9820
Page 7: ...RH 9820 v Belt cover Rear 0331B 0332B 0334B 0486B 0485B 0333B ...
Page 46: ...4 MECHANICAL DESCRIPTIONS RH 9820 37 ...
Page 58: ...5 DISASSEMBLY RH 9820 49 5 10 Lubrication 1089B ...
Page 124: ...6 ASSEMBLY RH 9820 115 6 19 Covers 1064B ...
Page 210: ...8 ELECTRICAL MECHANISM 201 RH 9820 PMD P C board Power supply motor P C board 0693B 4593Q ...
Page 211: ...8 ELECTRICAL MECHANISM 202 RH 9820 Panel P C board 0694B ...
Page 217: ...8 ELECTRICAL MECHANISM 208 RH 9820 0761B ...
Page 218: ...8 ELECTRICAL MECHANISM 209 RH 9820 0762B ...
Page 236: ...SERVICE MANUAL RH 9820 I6100920B 2007 03 B 1 Printed in Japan ...