- 17 -
4.
ADJUSTMENT OF NEEDLE DROP POINT
STANDARD
The needle should enter 0.9 mm inward from the left end of the needle hole in the needle plate when the hand
wheel is turned.
ADJUSTMENT
1.
Turn the hand wheel by hand and observe the position of the needle in the needle hole.
2.
Loosen the screw and the set screw of the presser unit.
3.
Move the presser unit right or left so that the needle point locates 0.9 mm inward from the left end of the
needle hole.
4.
Tighten the screw and the set screw of the presser unit.
5.
Turn the hand wheel by hand and recheck the needle drop point.