III-32
(7)
Solder the six switch ASSY harnesses onto the main PCB unit.
Note: Be careful to the direction of the switch ASSY harness and not to stick out from the
designated place when soldering switch ASSY harness.
CAUTION: When soldering, use the lead-free solder.
(PT-1900/1910)
(PT-1850)
Fig. 3.2-12 Installing the Main Frame ASSY (2)
Orange
Blue
Yellow
Red
Green
K1
K2
K3
K4
K5
Main frame ASSY
Upper cover
Main PCB unit
Switch ASSY harness
Black
K0
Main frame ASSY
Orange
Blue
Yellow
Red
Green
K1
K2
K3
K4
K5
K0
Black
Switch ASSY harness
Main PCB unit
Upper cover
Summary of Contents for P-Touch PT-1850
Page 1: ...SERVICE MANUAL MODEL PT 1900 1910 1850 ...
Page 9: ...I 4 PT 1900 U S A CANADA PT 1910 U S A Fig 1 1 2 Key Arrangement 1 ...
Page 10: ...I 5 PT 1900 AUSTRALIA Fig 1 1 2 Key Arrangement 2 ...
Page 11: ...I 6 PT 1850 FRENCH Fig 1 1 2 Key Arrangement 3 ...
Page 12: ...I 7 PT 1850 GERMAN Fig 1 1 2 Key Arrangement 4 ...
Page 13: ...I 8 PT 1850 U K Fig 1 1 2 Key Arrangement 5 ...
Page 14: ...I 9 PT 1850 BELGIUM Fig 1 1 2 Key Arrangement 6 ...
Page 51: ...III 23 Fig 3 2 3 Installing the Power Supply PCB 2 ...
Page 77: ...IV 2 4 1 3 Troubleshooting Flows 1 Tape feeding failure ...
Page 78: ...IV 3 ...
Page 79: ...IV 4 2 Printing failure ...
Page 80: ...IV 5 ...
Page 81: ...IV 6 3 Powering failure Nothing appears on the LCD ...
Page 82: ...IV 7 ...
Page 83: ...IV 8 4 No key entry possible ...
Page 84: ...IV 9 5 Tape cutting failure ...
Page 85: ...IV 10 6 Abnormal LCD indication ...
Page 86: ...IV 11 7 Tape cassette type not identified ...
Page 98: ......
Page 99: ......
Page 100: ......