S-7200B
6. ADJUSTMENTS
34
6-13. Adjusting the needle up stop position (When using the operation panel)
1. While pressing the needle up/down key (1), turn on the
power switch.
2. “n.0 xx” will appear in green in the main display (2).
(“xx” is the setting value for the needle up stop position,
and “0” is the default setting.)
3. Press the or key (3) to change the setting value
for the needle up stop position.
•
If you press the key, the setting value will increase
up to 20 and the needle up stop position will become
lower.
•
If you press the key, the setting value will decrease
down to -10 and the needle up stop position will
become higher.
4. Press the ENTER key (4) for two seconds or more.
A long buzzer will sound and the main display (2) will
change to stitch number display mode. (This completes
the needle up stop position setting.)
* A setting value of “10” corresponds to an angle of rotation
of approximately 10
°
for the upper shaft.
* If DIP switch 3 is not set to OFF, this adjustment cannot be
carried out.
2210M
3657M
2138M 2139M
(–10 – 20)
Becomes higher
Becomes lower