LH4-B800E
6 - 8
6. ELECTRIC MECHANISM
P10 [HEAD]
Pin No.
Signal name
Symptoms resulting mainly from poor contact
1
Emergency stop NC signal
The emergency stop switch does not operate.
The thread breakage detection does not operate normally.
2
0V
3
Emergency stop NO signal
4
+24V
5
-
6
0V
7
+5V
8
Thread breakage detection signal
9
-
10
P8V (+8V)
11
0V
P11 [ORG]
Pin No.
Signal name
Symptoms resulting mainly from poor contact
1
+24V
The home position can not be found.
One of error E-05, E-06 and E-07 is displayed.
2
Zigzag home position signal
3
0V
4
+5V
5
+24V
6
Feed home position signal
7
0V
8
+5V
9
+24V
10
Presser foot home position signal
11
0V
12
+5V
P13 [FAN12]
Pin No.
Signal name
Symptoms resulting mainly from poor contact
1
+24V
The exhaust fan does not operate.
Error E-42 is displayed.
2
FAN1 signal
3
0V