5-6
Confidential
1.3.6 Save NetConfig data
<Function>
This function is used to save NetConfig data to the USB flash memory.
<Operation Procedure>
(1) In function number selection mode of the maintenance mode, press the [to USB] key
fifteen times. The Error LED, the Power LED, the to PC LED and the to USB LED light.
(2) Insert the USB flash memory into the USB terminal.
(3) Press the [X] key. NetConfig data is saved in the USB flash memory and the machine
returns to the ready state.
Dirt on the second side
CIS, calibration sheet,
or gray tape
(detected that the data
acquired on the second
side CIS was out of
normal range)
Clean the second side
CIS or calibration
sheet. Or replace the
second side CIS.
Dirt on the first side
CIS, calibration sheet,
or gray tape
(detected that the data
acquired on the first
side CIS was out of
normal range)
Clean the first side CIS
or calibration sheet. Or
replace the first side
CIS.
Dirt on the first and
second side CIS,
calibration sheet, or
gray tape
(detected that the data
acquired on the first
and second side CIS
was out of normal
range)
Clean the first side CIS
or calibration sheet. Or
replace the first and
second side CIS.
LED
Cause
Remedy
1
2
3
1
2
3
1
2
3
Summary of Contents for ImageCenter ADS-2400N
Page 23: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path Front side Back side ...
Page 46: ...3 2 Confidential 2 PACKING ...
Page 49: ...3 5 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 50: ...3 6 Confidential 6 OVERVIEW OF GEARS There are no gears to be disassembled ...
Page 96: ...4 3 Confidential 6 Click the Machine Info The firmware version is displayed ...