4.1.17 A scanning error occurred while scanning the image.
4.1.18 Email address has more than 64 characters.
The number of email addresses has exceeded the specified amount.
4.1.19 Cannot connect to PC.
Step
Cause
Remedy
1
Program malfunction
Install the latest version of the firmware.
(Refer to
2
The maintenance mode function
"Acquire white level data and set
CIS scan area" are not set.
Execute the maintenance mode function
"Acquire white level data and set CIS scan
area". (Refer to
3
First side or second side CIS
unit failure
Replace the first side or second side CIS unit.
4
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Check the email address settings.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Reconnect the USB cable.
- Replace the USB cable.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.