1-10
Confidential
4)
Cartridge position error
Identification failure for a new toner cartridge.
5)
No paper fed tray 1
No paper in Tray (T1)
User Check
• Install the toner cartridges into the machine properly.
Step
Cause
Remedy
1
Power off or front cover opened
while detecting a new toner
cartridge.
Reset the developing bias voltage and
develop roller counter. (Refer to
in Chapter 5.)
User Check
• Check if the paper is loaded into the paper tray correctly. Then press the [Go] button.
Step
Cause
Remedy
1
Registration front sensor failure
Check the sensor performance following
the procedure in
(Chapter 5).
If any problem occurs, replace the
registration front sensor PCB ASSY.
2
Lift arm and roller holder ASSY not
assembled correctly
Be sure to put the boss of the roller holder
ASSY into the hole on the lift arm securely.
3
Harness connection failure of
registration front sensor PCB
ASSY
Check the harness connections of the
registration front sensor PCB ASSY, and
reconnect it.
4
Harness connection failure of T1
solenoid
Check the harness connections of the T1
solenoid, and reconnect it.
5
Plate-up function malfunction
Replace the paper tray.
6
Toner LED PCB ASSY failure
Replace the toner LED PCB ASSY.
7
Main PCB ASSY failure
Replace the main PCB ASSY.