3-80
Confidential
(2) Remove the four screws (main PCB B57U081) or three screws (main PCB B57U082) and
take the main PCB shield up and off the main PCB.
(3) Unlatch the SDAA enclosure by pinching its right and left sides and remove it from the
main PCB.
(4) Disconnect the MJ (LINE) harness (2-wire, yellow)*
from the main PCB and remove it
from the cable guide on the SDAA cover*.
* For MFC only
(3_074)
Main PCB B57U082
Main PCB B57U081
Main PCB shield
Main PCB shield
Taptite, cup S
M3x6
Taptite, cup S
M3x6
MJ (LINE) harness *
(yellow)
SDAA cover *
Wireless LAN PCB harness
Main PCB
Summary of Contents for DCP-J925DW
Page 17: ...xiv Confidential ...
Page 18: ...xv Confidential ...
Page 19: ...xvi Confidential ...
Page 20: ...xvii Confidential ...
Page 21: ...xviii Confidential ...
Page 44: ...1 23 Confidential 1 0 08 inches 2 mm or greater curve may cause jams to occur ...
Page 140: ...3 3 Confidential 2 PACKING ...
Page 281: ...4 28 Confidential ADF Copy Chart C A B D ...
Page 292: ...5 8 Confidential Print Pattern for Creating Head Calibration Data ...
Page 294: ...5 10 Confidential Scanning Compensation Data List ...
Page 297: ...5 13 Confidential Nozzle Test Pattern ...
Page 300: ...5 16 Confidential Configuration List ...
Page 303: ...5 19 Confidential MFCJ430W J432W MFCJ625DW J825DW Key Entry Order ...
Page 318: ...5 34 Confidential PF EXIT Adjust Check Pattern Paper feed roller ...
Page 319: ...5 35 Confidential EXIT Adjust Check Pattern 1 ...
Page 320: ...5 36 Confidential EXIT Adjust Check Pattern 2 ...
Page 321: ...5 37 Confidential EXIT Adjust Check Pattern 3 ...
Page 322: ...5 38 Confidential KEISEN2 LF300 EXIT ADJUST PATTERN ...
Page 327: ...5 43 Confidential Vertical Alignment Check Pattern ...
Page 331: ...5 47 Confidential Left Right Top and Bottom Margin Check Pattern ...
Page 367: ...6 4 Confidential Power supply PCB 100 V series ...
Page 368: ...6 5 Confidential Power supply PCB 200 V series ...
Page 369: ...6 6 Confidential Wiring diagrams ...