8. LIST OF ERROR CODES
BAS-326H-484, BAS-326H-484 SF
52
Communication and memory-related errors
Code
Cause of error and remedy
E401
Communication error was detected between the main board and the motor board when the power was turned on.
Turn off the power, and then check that connector P5 on the main board and the connector P2 on the motor
board are properly inserted.
E410
Communication error was detected between the main and the panel.
Turn off the power, and then check that the connector P10 on the programmer main board inside the LCD panel,
the connector on the right side of the control box, connectors P5 and P32 on the main board and the connector
P2 on the motor board are properly inserted.
E411
Communication error was detected between the main and the motor board.
Turn off the power, and then check that the connector P5 on the main board and the connector P2 on the motor
board are properly inserted.
E420
No storage media is inserted.
Press the RESET key to clear the error.
Insert the storage media and then try again.
E421
The program number is invalid or it has no corresponding data.
Press the RESET key to clear the error.
Check that data for this program number is present.
E422
Error occurred while reading.
Press the RESET key to clear the error.
Check the data.
E425
Error occurred while writing to storage media.
Check the storage media. It may be write-protected.
There is a possibility of a failure of the storage media or free space shortage of storage media.
Press the RESET key to clear the error.
Use the specified storage media.
E427
The program containing the specified program has been cleared.
Press the RESET key to clear the error.
E430
Cannot be accessed to the main board (flash memory).
Turn off the power, and then turn it back on again.
E435
Cannot be accessed to the programmer main board (flash memory).
Turn off the power, and then turn it back on again.
E440
Cannot be accessed to the main board (EEPROM).
Turn off the power, and then turn it back on again.
E445
Cannot be accessed to the programmer main board (EEPROM).
Turn off the power, and then turn it back on again.
E450
Model selection cannot be read from the machine head detector.
Turn off the power, and then check that the connector P16 on the main board is properly inserted.
E452
Machine head detector is not connected.
Turn off the power, and then check that the connector P16 on the main board is properly inserted.
If you press the RESET key to clear the error, you can restart the machine using the backup data in the machine
head detector.
E453
Problem with data in machine head detector.
Turn off the power, and then turn it back on again.
E454
Problem with data in machine head detector.
Press the RESET key to clear the error and then data is recovered.
E471
The program number is invalid or it has no corresponding data. Press the RESET key to clear the error.
Check that data for this program number is present in the internal memory.
E474
Internal memory is full and copying is not possible.
Press the RESET key to clear the error. Delete the sewing data.