7. STANDARD ADJUSTMENTS
BAS-326H-484, BAS-326H-484 SF
47
7-16. Adjusting the work clamp lift amount
The maximum lift amount for the work clamp is 27.5 mm above the surface of the needle plate.
1. Turn on the air, and then depress the work clamp switch (1) to raise the work clamps (2).
2. Loosen the two bolts (4) of the work clamp arm lever (3), and move the work clamp arm lever (3) up or down to adjust.
7-17. Adjusting the air pressure
Lift up the handle (2) of the regulator (1) and then turn it to
adjust the air pressure to 0.5 MPa.
After adjustment is complete, push the handle (2)
downward to lock it.
If water has collected in the bottle of the regulator (1), turn
the drain cock (3) in the direction indicated by an arrow to
drain the water.
NOTE:
Open the air cock (4) slowly.