8.

Attach the flexible arm to the head band by lining up the wide end of the 

flexible arm with the threads on the head band, and rotating the dial on 

the ball joint clockwise to tighten.

9.

Run the head display cable through the cable channel on the flexible 

arm, and then through the cable channel on the top of the head band. 

Secure the head display cable into the clip on the end of the head band, 

to prevent it from coming loose during operation.

10.

Connect the head display cable to the control box and press the power 

button to turn the AiRScouter on. Press the image rotation button to 

rotate the image by 180° so that it is no longer upside-down.

Power supply

Using an External Battery

You can use a third-party USB battery as an external power source to 

extend the operating time of the AiRScouter beyond that supported by 

the internal battery.

1.

Before connecting an external battery to the control box, ensure that 

the  external battery has been fully charged. (For more information 

on charging a third-party USB battery, see the battery’s manual.)

2.

Connect the Micro-USB B plug of a USB Type-A to Micro-USB B cable 

to the Micro-USB B port of the control box.

3.

Connect the USB Type-A plug to the USB Type-A port of the external 

battery.

4.

The external power LED on the control panel will turn orange when an 

external battery is connected and supplying power to the AiRScouter.

• The external power LED will turn off when the external battery is 

discharged. 

• If the internal battery is charged, the system will automatically switch 

to use the internal battery.

Note

To increase the stiffness of the arm during operation, you can tighten 

one or both ball joints by rotating their respective dials clockwise.

Note

When attaching the head display cable to the flexible arm and head 

band, ensure that you leave enough slack so that you do not pull the 

head display cable during adjustment and operation.

Note

To return the AiRScouter to left-eyed viewing, follow the same 

instructions, using the flexible arm for left eye instead of the flexible arm 

for right eye.

Important

The AiRScouter can use the following power supplies:

- The AC adapter supplied in the box
- The internal battery supplied for use inside the control box
- An external battery (for example a third-party USB battery) 

that supplies a voltage of DC 5 V and a current of at least 1 A

If multiple power supplies are connected to the AiRScouter at the same 

time, they will be prioritised in this order:

a

AC adapter

b

External battery

c

Internal battery

Example:

- If an external battery is disconnected while the AiRScouter is in use, 

the system will switch to using the internal battery.

- If an external battery is connected while the AiRScouter is using the 

internal battery, the system will switch to using the external battery.

The internal battery will not charge while the AiRScouter is turned on. 

To charge the internal battery, you must power off the AiRScouter and 

connect the AC adapter.

The external battery cannot be used to charge the internal battery. 

The internal battery can only be charged by the AC adapter.

You cannot charge the AiRScouter by connecting it to a computer with 

a USB cable.

If a USB-AC conversion adapter is used as the external power supply for 

the AiRScouter, ensure that the adapter supplies a voltage of DC 5 V 

and a current of at least 1 A.

If the AiRScouter becomes hot to the touch due to continuous use, or if 

the environmental conditions are outside of the recommended range, 

the external power LED will begin to flash quickly. While the AiRScouter 

is in this state, the internal battery cannot be charged.

Important

Only use a third-party external battery that can supply a voltage of 

DC 5 V and a current of at least 1 A.

The external battery cannot be used to charge the internal battery. 

The internal battery can only be charged by the AC adapter while the 

AiRScouter is powered off.

Summary of Contents for AiRScouter WD-360B

Page 1: ...le in the case it may become damaged a Focus Adjustment Dial Adjusts the focus of the image on the head display by changing the focal length of the optics from 30 cm to infinity b Head Display Cable Connects the head display to the control box and transmits power and video signals to the head display c Eyecup When attached prevents the head display from touching the user s eye a Head Band Attaches...

Page 2: ...a third party USB battery LED Indications lit flashing off a Display LED Green b Key Lock LED Orange c Internal Battery LED Orange d External Power LED Orange When the AC adapter is connected d External Power LED Orange When an external battery is connected Control Box a b c d e a b c d a b c d State Name Explanation Display ON The AiRScouter is receiving a compatible video signal from an external...

Page 3: ... The band should be positioned just above the forehead 2 To secure the head display cable to your clothing use the cable clip Turn the power on Press the power button to turn the AiRScouter on The LED under the power button will turn green Adjust the position of the Head Display 1 Loosen the ball joints by turning the dials on either end of the flexible arm counter clockwise 2 Adjust the position ...

Page 4: ... displayed at the original resolution Enlarge the centre portion of the image is enlarged to fit the head display screen This mode is useful for focussing or to check fine details in the image Reduce the image is reduced in size to fit the head display screen this mode is useful if you cannot clearly see details around the edges of the image in Normal mode Pressing the mode button will change the ...

Page 5: ...m the cable channel on the head band and from the cable channel on the flexible arm 3 Rotate the dial on the ball joint between the flexible arm and the head band clockwise until the flexible arm is separated from the head band 4 Rotate the dial on the ball joint between the flexible arm and the head display clockwise until the flexible arm is separated from the head display 5 Turn the head band o...

Page 6: ...t pull the head display cable during adjustment and operation Note To return the AiRScouter to left eyed viewing follow the same instructions using the flexible arm for left eye instead of the flexible arm for right eye Important The AiRScouter can use the following power supplies The AC adapter supplied in the box The internal battery supplied for use inside the control box An external battery fo...

Page 7: ... when an external battery is connected the external power LED orange does not light Does the external battery provide the current of at least 1 A Use an external battery that provides a voltage of 5 V DC and current of at least 1 A If after reading the troubleshooting tips you are unable to resolve your problem visit the Brother Solutions Center at support brother com The internal battery discharg...

Page 8: ...e device if the control box gets extremely hot Inserting the Li ion Rechargeable Battery into the Control Box If the Li ion rechargeable battery was removed perform the steps listed above in reverse to insert it again How to charge the Li ion Rechargeable Battery The Li ion rechargeable battery can be charged only by using the included AC adapter To charge the battery follow these steps 1 Power of...

Reviews: