In
spection and Adjustment
In
spection and Adjustment
4 - 14
Adjustment
Left and right needle clearance
[Standard]
At pattern selection dial [3] (zigzag stitch) and stitch width dial [5] (maximum), the left
and right needle drop position should be the same to the center of the needle hole.
[Adjustment]
1. Remove the face plate and the accessory table.
2. Remove the presser foot.
3. Attach the size 90/14 needle.
4. Turn the pattern selection dial until the [3] is the topmost position.
5. Turn the stitch width dial until the [5] is the topmost position.
6. Loosen the screw
1
of the needle shaft holder assy.
7. Adjust the left/right needle drop position so that the same to the center of the needle hole by moving the position of
the needle shaft holder assy to the left and right.
8. Tighten the screw
1
of the needle shaft holder assy to secure the needle shaft holder assy to the base holder.
1
Pulley
Pattern
selection dial
Stitch width dial
Bolt, Socket
M3X6
Outer rotary hook assy
Left
Right
Hook point
Needle
top
Needle
top
Needle hole
Hook point
Needle shaft holder assy
Base holder
1
Hex wrench
2.5 mm
Bottom side view
Summary of Contents for AE2700
Page 1: ......
Page 2: ......
Page 3: ......
Page 30: ...2 14 Zigzag mechanism Basic Basic Zigzag mechanism location diagram BasicofDisassembly ...
Page 56: ...2 40 Zigzag mechanism Basic Basic Zigzag mechanism location diagram BasicofAssembly ...
Page 69: ...2 53 Main frame and Covers Basic Basic Main frame and Covers location diagram BasicofAssembly ...
Page 201: ...6 1 6 Motor 3P supply assy 6 2 LED lamp 6 4 Special Instructions of Wiring ...
Page 205: ......