Broseley THERMO VERONA DSA Installation And Operation Instructions Manual Download Page 18

18 

 

LIMITED

 

WARRANTY

 

 

This

 

appliance

 

must

 

be

 

installed

 

and

 

commissioned

 

by

 

a

 

fully

 

qualified,

 

registered

 

engineer.

 

A

 

“Declaration

 

of

 

completion

 

Certificate”

 

must

 

be

 

obtained

 

for

 

the

 

installation

 

and

 

retained

 

by

 

the

 

end

 

user.

 

Failure

 

to

 

comply

 

with

 

these

 

requirements

 

may

 

void

 

your

 

warranty.

 

You,

 

as

 

the

 

end

 

user,

 

have

 

a

 

contract

 

by

 

law

 

with

 

the

 

supplier

 

/

 

dealer

 

from

 

whom

 

you

 

purchased

 

the

 

product.

 

That

 

dealer

 

then

 

has

 

the

 

same

 

contract

 

with

 

the

 

manufacturer

 

or

 

wholesaler

 

and

 

these

 

have

 

a

 

contract

 

with

 

their

 

suppliers.

  

 

ALL

 

CLAIMS

 

MUST

 

FOLLOW

 

THIS

 

PROCEDURE.

 

 

Thank

 

you

 

for

 

choosing

 

a

 

Product

 

from

 

Broseley

 

Fires

 

Ltd

.

 

This

 

warranty

 

gives

 

you

 

specific

 

legal

 

rights.

 

The

 

statutory

 

rights

 

of

 

the

 

consumer

 

are

 

not

 

affected

 

by

 

the

 

warranty,

 

or

 

the

 

consumers’

 

rights

 

against

 

the

 

dealer

 

arising

 

from

 

their

 

sales

 

/

 

purchase

 

contract.

 

 

The

 

manufacturers’

 

warranty:

  

 

Your

 

Product

 

will

 

be

 

free

 

from

 

defective

 

parts,

 

material,

 

and

 

workmanship

 

at

 

the

 

time

 

of

 

its

 

original

 

purchase

 

for

 

a

 

period

 

of

 

one

 

(1)

 

year.

 

This

 

Warranty

 

will

 

become

 

active

 

as

 

of

 

one

 

month

 

from

 

the

 

date

 

of

 

delivery.

 

 

This

 

warranty

 

does

 

not

 

cover

 

any

 

failure

 

of

 

the

 

unit

 

due

 

to

 

normal

 

wear

 

and

 

tear,

 

misuse,

 

abuse,

 

accident,

 

illegal

 

modification,

 

illegal

 

installation

 

or

 

repair,

 

damage

 

resulting

 

from

 

improper

 

use

 

or

 

failure

 

to

 

maintain

 

the

 

product.

 

Variations

 

in

 

color

 

and

 

texture

 

are

 

a

 

natural

 

characteristic

 

of

 

cast

 

iron

 

products.

 

Colour

 

changes

 

may

 

result

 

from

 

exposure

 

to

 

light

 

and

 

other

 

elements

 

which

 

are

 

a

 

part

 

of

 

the

 

aging

 

process.

 

These

 

material

 

variations

 

and

 

changes

 

are

 

not

 

covered

 

by

 

this

 

warranty.

 

 

If

 

during

 

the

 

warranty

 

period,

 

this

 

Product

 

fails

 

to

 

operate

 

under

 

normal

 

use

 

and

 

service,

 

due

 

to

 

defects

 

in

 

material

 

and

 

/

 

or

 

workmanship,

 

Broseley

 

Fires

 

will

 

either

 

repair

 

or

 

replace

 

the

 

product.The

 

repaired

 

or

 

replaced

 

product

 

shall

 

be

 

warranted

 

for

 

the

 

remaining

 

period

 

of

 

the

 

original

 

warranty

 

+

 

the

 

time

 

taken

 

to

 

days

 

from

 

the

 

date

 

of

 

repair,

 

whichever

 

is

 

longer.

 

 

Repair

 

or

 

replacement

 

may

 

involve

 

the

 

use

 

of

 

functionally

 

equivalent

 

reconditioned

 

units.

 

Replaced

 

parts

 

or

 

components

 

will

 

become

 

the

 

property

 

of

 

Broseley

 

Fires.

  

 

Should

 

you

 

wish

 

to

 

claim

 

under

 

the

 

warranty,

 

please

 

contact

 

the

 

supplier

 

/

 

dealer

 

from

 

whom

 

you

 

purchased

 

the

 

appliance.

  

Do

 

not

 

claim

 

directly

 

to

 

Broseley

 

Fires,

 

as

 

they

 

are

 

unable

 

to

 

process

 

any

 

direct

 

claim

 

from

 

an

 

end

 

user.

 

 

Product

 

design

 

and

 

any

 

specifications

 

are

 

subject

 

to

 

change

 

without

 

notice.

 

This

 

is

 

due

 

to

 

our

 

continuous

 

product

 

development

 

and

 

improvement.

 

The

 

buyer

 

will

 

not

 

be

 

entitled

 

to

 

request

 

free

 

upgrades

 

to

 

the

 

new

 

design

 

or

 

compensation

 

for

 

previously

 

purchased

 

products

 

or

 

any

 

products

 

on

 

order.

  

 

 

This

 

Warranty

 

covers

 

all

 

Broseley

 

Fires

 

costs

 

within

 

the

 

Warranty

 

period.

 

 

If

 

the

 

appliance

 

remains

 

uninstalled

 

for

 

a

 

period

 

greater

 

than

 

six

 

months

 

from

 

date

 

of

 

delivery

 

the

 

Warranty

 

will

 

become

 

active

 

six

 

months

 

from

 

the

 

date

 

of

 

original

 

invoice

 

to

 

the

 

distributor.

 

 

I

N

 

NO

 

EVENT

 

SHALL

 

B

ROSELEY

 

F

IRES

 

BE

 

LIABLE

 

FOR

 

INCIDENTAL

 

OR

 

CONCEQUENTIAL

 

DAMAGES

 

OF

 

ANY

 

NATURE

 

WHATSOEVER

,

 

INCLUDING

 

BUT

 

NOT

 

LIMITED

 

TO

 

LOST

 

PROFITS

 

OR

 

COMMERCIAL

 

LOSS

,

 

TO

 

THE

 

FULL

 

EXTENT

 

THOSE

 

DAMAGES

 

CAN

 

BE

 

DISCLAIMED

 

BY

 

LAW

.

 

(if

 

applicable)

 

 

NON

 ‐ 

COVERAGE

 

OF

 

THE

 

GUARANTEE

 

 

The

 

consumable

 

items

 

within

 

the

 

product

 

are

 

not

 

covered

 

by

 

the

 

warranty,

 

nor

 

is

 

the

 

glass

 

If

 

the

 

end

user’s

 

claim

 

should

 

not

 

be

 

covered

 

by

 

this

 

guarantee,

 

the

 

end

user

 

shall

 

be

 

liable

 

for

 

costs

 

incurred

 

by

 

Broseley

 

Fires

 

such

 

as

 

callout

 

and

 

inspection

 

costs

 

for

 

examination

 

of

 

the

 

product,

 

transportation

 

costs

 

of

 

the

 

product

 

as

 

well

 

as

 

any

 

other

 

relevant

 

costs.

  

If,

 

after

 

having

 

been

 

informed

 

about

 

the

 

non

coverage

 

of

 

the

 

guarantee,

 

the

 

end

user

 

wants

 

to

 

have

 

the

 

repairs

 

done,

 

the

 

end

user

 

shall

 

additionally

 

pay

 

for

 

any

 

spare

 

parts

 

used

 

and

 

for

 

the

 

labour

 

and

 

transportation

 

costs

 

incurred.

 

If

 

repairs

 

are

 

carried

 

out

 

under

 

this

 

guarantee,

 

the

 

remaining

 

guarantee

 

period

 

for

 

the

 

product

 

shall

 

be

 

extended

 

by

 

the

 

period

 

of

 

time

 

that

 

has

 

elapsed

 

since

 

the

 

complaint

 

was

 

officially

 

logged

 

with

 

Broseley

 

Fires

 

until

 

the

 

repairs

 

have

 

been

 

completed

 

 

A

 

COPY

 

OF

 

OUR

 

FULL

 

TERMS

 

AND

 

CONDITIONS

 

IS

 

AVAILABLE

 

ON

 

REQUEST

.

 

 

**

 

End

user

 

means

 

the

 

natural

 

or

 

legal

 

person

 

who

 

owns

 

the

 

product

 

and

 

who

 

has

 

not

 

acquired

 

it

 

with

 

a

 

view

 

to

 

reselling

 

or

 

installing

 

it

 

in

 

the

 

course

 

of

 

business

 

 

Summary of Contents for THERMO VERONA DSA

Page 1: ...NING BOILER STOVE PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OPERATING OR SERVICING THIS APPLIANCE A Declaration of Completion Certificate must be obtained for the installation and retained by the end user Failure to comply with these requirements may void the warranty Revision TJ09b ...

Page 2: ...ace within the firebox to maximize the heat output of the appliance and to minimize the discharge of particulate emissions to the atmosphere It is important therefore for appliances to be operated in accordance with our instructions in a manner that maintains a high temperature in the firebox with an adequate supply of air to ensure efficient combustion A good indication of efficient combustion is...

Page 3: ...OSAL 10 0 OPERATING IN TRANSITION PERIODS SUMMER 11 0 MAINTENANCE CLEANING THE APPLIANCE 12A RECOMMENDED CLEANING PRODUCTS 12B DAILY CARE 12C CLEANING THE OUTSIDE OF THE APPLIANCE 12D ASH REMOVAL 12E GLASS CLEANING 12F FLUE MAINTENANCE 12G ROPE SEALS 12H AIR CONTROLS 13 0 INSTALLATION OF THE APPLIANCE 13A FLUE REQUIREMENTS 13B LINING THE FLUE 14 SITING THE APPLIANCE 14A HEARTH REQUIREMENTS 15 ADDI...

Page 4: ...tem during the whole year The THERMO VERONA DSA stove is made of cast iron and plates of steel metal sheet The fire chamber is internally lined with cast iron firebricks There is a turning and extractable grate The stove is equipped with a panoramic door with ceramic glass resistant up to 700 ºC this allows a wonderful view of the flame picture whilst also preventing outputs of sparks and smoke Th...

Page 5: ...OLS The stove is fitted with controls that adjust the flow of air into the unit It is very important that these controls are fully understood in order to achieve the best results from your stove When operating the controls ensure that they are used in small increments and not changed by large amounts suddenly Do not use them like an on off switch It is important that the following controls are use...

Page 6: ...n t empty When wanting to control the stove using the thermostatic control the primary and secondary air controls can be shut According to the chosen position of the thermostat dial the damper will react slowly and alter the combustible air entering the unit This is how a fire would naturally respond to changing air supply As it is a high precision device we recommend moving the lever slowly and w...

Page 7: ...e into consideration ease of splitting ease of ignition and burning how much smoke it produces and its coaling qualities Coaling refers to the ability of a species of wood to form a long lasting bed of hot coals when burned Coaling qualities improve with higher density 5C Hot Plate Operation To operate your hot plate on your stove lift the hot plate cover upwards always using the glove supplied un...

Page 8: ...ir controls The thermostat control should be set to number 5 The ignition control should be pushed in This will open the damper to the chimney fully and create the best condition for the lighting of the fire It will take a few minutes for the fire to establish itself When the fire is burning hot add small pieces of hardwood Keep all the draft controls fully open till a bed of hot glowing embers is...

Page 9: ...ers can stay dormant for long periods when buried in ashes These will then flare up again when exposed to oxygen some knowledge of proper ash removal is required for safety Here are the important points Remove ashes to a metal container using a small trowel Never vacuum the ashes unless it is a genuine Ash Vac This is a vacuum you can buy at hearth shops it is specifically designed for ash removal...

Page 10: ...eaners paint solvents biological powders coarse abrasives or salt Never mix different products as they may cause a chemical reaction with each other and cause harm to either you or the appliance 12A RECOMMENDED CLEANING PRODUCTS For the more stubborn stains a mildly abrasive cleaner should be used such as Astonish This is safe to use on enamel surfaces Do not use Astonish on the chrome components ...

Page 11: ...e then you can dip a damp cloth in the ash and use this to scrub the glass clean 12F FLUE MAINTAINENCE If your appliance is installed into an existing chimney you will need to clean the chimney as well as the flue pipe at least twice a year To do this you will need the appropriate sized chimney brush and rods Call a certified chimney sweep National Association of Chimney Sweeps or other qualified ...

Page 12: ...nd sweeping of the flue Flue pipe should be fitted inside the flue pipe collar spigot to prevent creosote and condensates from running down onto the top of the appliance All flue pipe has to be suitable for solid fuel and fitted in accordance with building regulations whilst complying with current legislation and manufacturers instructions If excessive draw is present then a suitable draught stabi...

Page 13: ...BLE MATERIALS The minimum distance from any NON FLAMMABLE object or one that is NOT sensitive to heat stone brick slate etc and from materials with non flammable structure must be 100 mm s to the rear and on both sides PLEASE REFER TO BUILDING REGULATIONS WALLS ADJACENT TO HEARTHS for further information Where the hearth abuts a wall and the appliance is more than 50mm but not more than 300mm away...

Page 14: ...14 16 0 POSITIONING THE SMOKE DEFLECTOR PLATE ...

Page 15: ... Before connecting up the boiler the installer must ensure that they thoroughly flush all of the systems pipes in order to remove any residue which could compromise the correct operation of all system components Pumps valves etc It is also important to verify the chimney has sufficient draught there are no blockages and that no other appliance exhausts are inserted into the flue 20 0 FILLING UP TH...

Page 16: ...e so has additional connections shown in the diagram below These connections currently cannot be used in the UK however you will need to plug connection B as this is an open vessel into the boiler itself Connections C and A should be left open to the environment as they are a separate coil from the internal boiler of the stove ...

Page 17: ... No COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 5TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 6TH YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COM...

Page 18: ...Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance Do not claim directly to Broseley Fires as they are unable to process any direct claim from an end user Product design and any specifications are subject to change without notice This is due to our continuous pr...

Reviews: