MS10-11C Issue 4d
30
Commissioning & Handover
Ensure loose parts are fitted in accordance with the instructions for “Assembly” given
previously. On completion of the installation, allow a suitable period of time for any fire
cement and mortar to dry out; a small fire may then be lit and checked to ensure the
smoke and fumes are taken from the stove up the chimney and emitted safely outdoors.
Do not run at full output for at least 24 hours.
On completion of the installation and commissioning, ensure that this installation and
operation manual for the stove is left with the customer. Ensure the customer is advised on
the correct use of the appliance with the fuels likely to be used on the stove and warn them
to use only the recommended fuels for the stove.
Advise the user what they should do if smoke or fumes be emitted from the stove. The
customer should be warned to use a fireguard to BS 6539 in the presence of children,
aged and/or infirm persons. Advise the user not to fit an extractor fan in the same room as
the stove as this can cause the stove to emit fumes into the room.
A commissioning certificate MUST be given to the client once
the installation is complete. Th commissioning form on page
41-42 of these instructions should also be completed.