background image

 

 

the elements necessary for the electrical connection (connector and cable, 3). The Ex d Type 
0813 angle sensor is always equipped with a threaded pin (4) for electrical potential equali-
sation (this is optional in the other types). Base plate and housing are made from an alumini-
um alloy as standard; stainless steel is available as an option. 

Figure 2 shows the typical installation conditions: 

 

Figure 2: Installation conditions in an example for a crane boom 

The  angle  sensor  (1)  is  usually  fixed  at  the  installation  site  to  the  appropriately  designed 
seatings (2) using securing elements (3). The normal to the measuring plane (4) is perpen-
dicular to the direction of gravity (5). The measurement electronics measure the angular po-
sition (6) of the angle sensor in the measuring plane and output this as an electrical signal. 

Versions  with  two  measuring  systems,  either  with  output  signals  on  separate  connect-
ors/cables  or  combined  in  one  connector/cable,  are  available  as  options.  More  information 
can  be  found  in  the  technical  data  sheets,  which  can  be  obtained  free  of  charge  from 
BROSA. 

1.2  Information on explosion protection 

The Ex d type 0813 angle sensor is encapsulated as pressure-resistant and thus suitable for 
use in potentially explosive atmospheres. The following specifications apply: 

Ignition protection types: 

o

  II 2G Ex d IIC T4 Gb / Ex d IIC T4 Gb 

o

  II 2G Ex d IIB T4 Gb / Ex d IIB T4 Gb 

Certificate numbers: 

4

1

2

3

5

6

Summary of Contents for 0804

Page 1: ...to the direction of gravity in or on machines of all types This relationship is given by the defini tion of the measuring range in the form of defining the zero point and can be selected indi viduall...

Page 2: ...g plane 4 is perpen dicular to the direction of gravity 5 The measurement electronics measure the angular po sition 6 of the angle sensor in the measuring plane and output this as an electrical signal...

Page 3: ...side a region with a potentially explosive atmosphere 1 3 Label nameplate indication of measuring direction Each BROSA angle sensor is provided with a nameplate containing the information applica ble...

Page 4: ...sor measuring point assignment It must be ensured that the sensor to be installed is designed for use at the intended measuring point For this purpose check information on the nameplate in particular...

Page 5: ...onnected outside an area subject to explosion hazards it must be in line with the general requirements for electrical equipment Close attention must be paid to the connection of the potential equalisa...

Page 6: ...isting errors are to be identified and remedied If the test indicates an im proper sensor state it must be taken out of operation If a malfunction or damage is detected on the sensor it must be sent t...

Page 7: ...NG BROSA angle sensors contain traces of environmentally hazardous substanc es This is also true of the impurities created during use Contamination of the environment by these substances is to be prev...