Brooktrout PCI Analog Fax Linecard Installation and Replacement

EN/LZT 108 5829/6 R2A 

 

May 2002 Ericsson Enterprise AB

7

To install Brooktrout PCI analog fax cards:

1. Determine the channels each fax card will handle.

2. Select a PCI expansion slot.

3. Insert the card’s edge connector into the bus slot. Apply pressure only to the top edge of 

the board, and gently rock the card forward and backward to seat the edge connector into 
the slot.

4. Install the retaining screw.

5. Repeat steps 1–4 for each fax card.

6. After you have installed all fax cards, replace the cover on the platform.

7. Re-attach the power cord to the platform.

If the PCI fax card…

Then…

Replaces an existing fax card

Remove the existing fax card from the PCI 
expansion slot.

Adds fax ports to the system

If possible, select an empty PCI expansion slot that 
will be assigned IRQ 10. If you want to assign 
channel 0 to this fax card, be sure to select an 
expansion slot that will be assigned the lowest 
memory address range. Remove the slot’s retaining 
screw and access cover plate.

Summary of Contents for TR114+P2L

Page 1: ...mmend that you read this document in its entirety before disassembling the hardware IMPORTANT Consider the following issues when installing these PCI analog fax cards Because Ericsson sells Brooktrout...

Page 2: ...and make sure that you wear a grounding strap Document Conventions The RightFax software and documentation use the term channel to refer to both analog ports and digital channels The OneBox software...

Page 3: ...in disassembling the hardware platform make sure that you have the following required tools and equipment This document Phillips 2 screwdriver One or more Brooktrout PCI analog fax cards Manufacturer...

Page 4: ...each PCI fax card You have ordered appropriate telephone service for the PCI fax cards you have purchased IMPORTANT DID fax ports support inbound calls only DID ports cannot make callouts to deliver f...

Page 5: ...ed the power cord and removed the cover from the platform skip to the next section Installing Brooktrout PCI Analog Fax Cards in the Platform To prepare for service 1 Shut down all running programs 2...

Page 6: ...rm will be assigned fax channels 0 and 1 A second TR114 P2L with the next highest memory address range will be assigned fax channels 2 and 3 and so on for all TR114 P2L cards installed in the platform...

Page 7: ...tor into the slot 4 Install the retaining screw 5 Repeat steps 1 4 for each fax card 6 After you have installed all fax cards replace the cover on the platform 7 Re attach the power cord to the platfo...

Page 8: ...he cable assembly supplied with the fax card For the P2L the assembly is split at one end into two cables labeled A and B For the P4C and P4L the assembly is split into four cables labeled for ports o...

Page 9: ...k on the back of the power supply This contact block should look like the one shown in Figure 1 b Loosen the contact labeled 48V RET c Attach the black w green wire of the fax linecard s power cable t...

Page 10: ...tart ports 0 and 1 on this card Doing so can damage the fax card To connect the DID ports on a Brooktrout fax linecard to DID telephone lines 1 Locate the cable assembly supplied with the fax card The...

Page 11: ...blue screen in the Windows 2000 Server operating system Configuring the RightFax BoardServer If you have already installed or upgraded to RightFax version 8 0 you must configure the BoardServer utili...

Page 12: ...lacement 12 EN LZT 108 5829 6 R2A May 2002 Ericsson Enterprise AB Troubleshooting RightFax Fax Server Problems If you are having problems sending or receiving faxes with RightFax refer to the RightFax...