background image

Installation and Operation Manual

X-VA-1110-1140-eng

Part Number: 541B040AHG

March, 2008

Brooks

®

 1110 and 1140 Series

LIMITED WARRANTY

Seller warrants that the Goods manufactured by Seller will be free from defects in materials or workmanship under normal use
and service and that the Software will execute the programming instructions provided by Seller until the expiration of the
earlier of twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller.
Products purchased by Seller from a third party for resale to Buyer (“Resale Products”) shall carry only the warranty extended
by the original manufacturer.
All replacements or repairs necessitated by inadequate preventive maintenance, or by normal wear and usage, or by fault of
Buyer, or by unsuitable power sources or by attack or deterioration under unsuitable environmental conditions, or by abuse,
accident, alteration, misuse, improper installation, modification, repair, storage or handling, or any other cause not the fault of
Seller are not covered by this limited warranty, and shall be at Buyer’s expense.
Goods repaired and parts replaced during the warranty period shall be in warranty for the remainder of the original warranty
period or ninety (90) days, whichever is longer.  This limited warranty is the only warranty made by Seller and can be
amended only in a writing signed by an authorized representative of Seller.

BROOKS LOCAL AND WORLDWIDE SUPPORT

Brooks Instrument provides sales and service facilities around the world, ensuring quick delivery from local stock, timely
repairs and locally based sales and service facilities.
Our dedicated flow experts provide consultation and support, assuring successful applications of the Brooks flow
measurement and control products.
Calibration facilities are available in local sales and service offices. The primary standard calibration equipment to calibrate
our flow products is certified by our local Weights and Measures Authorities and traceable to the relevant international
standards.

START-UP SERVICE AND IN-SITU CALIBRATION

Brooks Instrument can provide start-up service prior to operation when required.
For some process applications, where ISO-9001 Quality Certification is important, it is mandatory to verify and/or (re)calibrate
the products periodically. In many cases this service can be provided under in-situ conditions, and the results will be traceable
to the relevant international quality standards.

CUSTOMER SEMINARS AND TRAINING

Brooks Instrument can provide customer seminars and dedicated training to engineers, end users and maintenance persons.
Please contact your nearest sales representative for more details.

HELP DESK

In case you need technical assistance:

Americas

 1-888-554-FLOW

Europe

 +(31) 318 549 290

Within Netherlands 

 0318 549 290

Asia

 +011-81-3-5633-7100

Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change
without notice.

TRADEMARKS
Brooks ........................................................... Brooks Instrument, LLC
Carboloy ............................................................. General Electric Co.
Full-View ....................................................... Brooks Instrument, LLC
Hastelloy C ........................................................ Haynes International
Monel .................................................... Inco Alloys International Inc.
Neoprene .......................................... E.I. DuPont de Nemours & Co.
Teflon ................................................ E.I. DuPont de Nemours & Co.
Viton ............................................... DuPont Performance Elastomers

Summary of Contents for Glass Tube Full-View 1110

Page 1: ...ion Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series 5 Model 1140 Full View Flowmeter Flange Connections Glass Tube Full View Flowmeters Model 1110 Full View Flo...

Page 2: ...marked on and supplied with the product Inform and educate your personnel in the proper installation operation and maintenance of the product Install your equipment as specified in the installation in...

Page 3: ...ch and chemicals to medical devices analytical instrumentation semiconductor manufacturing and more The Brooks product you have just received is of the highest quality available offering superior perf...

Page 4: ...Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Page 5: ...lers 1 7 Section 2 Installation 2 1 General 2 1 2 2 Receipt of Equipment 2 1 2 3 Recommended Storage Practice 2 1 2 4 Return Shipment 2 2 2 5 Transit Precautions 2 2 2 6 Removal form Storage 2 2 2 7 I...

Page 6: ...odel 1110 Exploded Parts Drawing Continued 5 3 5 1c Model 1110 Exploded Parts Drawing Continued 5 4 Tables Table Page Number Number 1 1 Pressure Ratings and PED Category 1 3 1 2 Connections 1 5 1 3 Ca...

Page 7: ...ctions Rugged dowel pin side plate construction Precision bore plain or ribbed borosilicate glass metering tubes Reliable externally adjustable packing glands for ease of maintenance Flanged or NPT co...

Page 8: ...um flow Ambient Temperature Limits 33 F to 125 F 1 C to 52 C Operating Fluid Temperature Limits Maximum 250 F 121 C for metallic end fittings Reduced ratings on meters with nonmetallic end fittings Re...

Page 9: ...3 Metal 100 100 100 NOTES 1 Maximum temperature rating for nonmetal end fittings is 150 F 66 C for all materials except PVC which is 140 F 2 Flanged unit pressure ratings are limited to ANSI flange ra...

Page 10: ...to comply could result in serious personal injury or property damage WARNING GLASS TUBE EXPLOSION HAZARD Packing Material Standard Teflon Neoprene Viton fluoroelastomers O rings Standard Teflon Optio...

Page 11: ...on 1 Introduction Model 1110 Model 1114 Model 1140 Model 1144 Meter Inlet Outlet Inlet Outlet Inlet Outlet Inlet Outlet Size Horizontal Vertical Horizontal Vertical NPT NPT Flange Flange 2 to 6 1 4 1...

Page 12: ...m scale length Flange dimensions apply to 150 300 raised face or flat face flanges All Dimension in Millimeters 1110 1140 1114 1144 Nominal Scale Length MM Nominal Scale Length MM Nominal Scale Length...

Page 13: ...DS FCA Figure 1 3 Float Types Spherical Lowest meter capacityandnoviscousfluids with medium capacity Type RV rib guided Highest immunity to viscous fluids with medium meter capacity Most stable Type...

Page 14: ...s 605 24 2 slpm 7 R 7M 25 1 Stn Steel 1 286 42 7 slpm Monel 1 360 44 8 slpm MAXIMUM FLOW RATE METER WATER AIR 14 7 PSIA SIZE TUBE FLOAT CC MIN AND 70 F 21 C GLASS 0 524 47 1 SCC MIN SAPPHIRE 1 02 73 3...

Page 15: ...5 380 9 8 0 0 R 9M 25 3 9 RV 87 3 92 14 84 14 0 17 0 16 25 460 2 16 0 30 9 RS 87 5 12 19 38 17 0 3 5 21 20 600 4 20 0 30 9 LJ 160 9 65 36 53 43 0 1 0 44 18 1 251 2 49 0 30 10 RV 64 4 54 17 18 8 0 14 0...

Page 16: ...8 2 4 20 35 576 3 13 0 0 R 9M 127 3 9 RV 87 5 55 21 01 18 1 17 0 23 30 659 9 21 0 30 9 RS 87 6 75 25 55 21 7 3 5 28 75 814 2 25 0 30 9 LJ 160 17 20 65 10 79 0 1 0 83 40 2 361 9 90 0 30 10 RV 64 4 28...

Page 17: ...0 14 76 23 0 16 3 16 40 464 4 26 0 0 9 9M 25 2 9 GS 75 5 22 19 76 34 0 2 1 21 60 611 7 38 0 0 9 LG 60 7 02 26 57 52 0 1 0 9 LG 88 8 91 33 72 81 0 1 0 9 LG 124 11 00 41 64 121 0 1 0 10 GV 54 5 60 21 20...

Page 18: ...1 12 Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series Section 1 Introduction THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Page 19: ...rsonProcess com www BrooksInstrument com Brooks Instrument Brooks Instrument Neonstraat 3 1 4 4 Kitasuna Koto Ku 6718 WX Ede Netherlands Tokyo 136 0073 Japan P O Box 428 Tel 011 81 3 5633 7100 6710 BK...

Page 20: ...s Fax 011 81 3 5633 7101 Tel 31 318 549 300 Email BrooksAs EmersonProcess com Fax 31 318 549 309 E mail BrooksEu EmersonProcess com All flow instruments returned to Brooks requires completion of Form...

Page 21: ...roper operation of the Full View flowmeter it must be mounted within 6 degrees of true vertical with the inlet connection at the bottom of the meter and the outlet at the top The use of a level is rec...

Page 22: ...2 4 Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series Section 2 Installation THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Page 23: ...the zero line on the scale the flowmeter is ready for operation If the zero lines are not aligned loosen the screws securing the scale and move it until the marks are in alignment Then tighten the sc...

Page 24: ...LOWMETER To initiate flow through a flowmeter using bypass piping refer to Figure 3 1 1 Close flowmeter isolation valves A and B 2 Fully open bypass valve C and slightly open control valve D 3 Initiat...

Page 25: ...anual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series Section 4 Maintenance and Cleaning 4 1 General This section provides the assembly and disassembly procedures for...

Page 26: ...es from the end fittings 6 Remove the inlet packing narrow end both gland rings polycarbonate sleeve Size 7 1 2 and larger and gland followers from the tube 7 Remove the float from the tube 8 Remove t...

Page 27: ...mount of silicone lubricant may be used 5 Install the end fittings onto the tube and packing assembly Insure that the outlet large end of the tube fits flush against the tube seat gasket in the outlet...

Page 28: ...4 4 Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series Section 4 Maintenance and Cleaning THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Page 29: ...X X X X X 7 Gland Followers X X X X X X 8 Float X X X 9 Inlet Float Stop Plug X X X 10 Inlet Spring Stop Valve stop X X X 11 Outlet Float stop X X X 12 Outlet Spring Stop Valve stop X X X 13 Inlet En...

Page 30: ...5 2 Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series Section 5 Accessories Figure 5 1a Model 1110 Exploded Parts Drawing...

Page 31: ...5 3 Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series Section 5 Accessories Figure 5 1b Model 1110 Exploded Parts Drawing Continued...

Page 32: ...5 4 Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series Section 5 Accessories Figure 5 1c Model 1110 Exploded Parts Drawing Continued...

Page 33: ...Installation and Operation Manual X VA 1110 1140 eng Part Number 541B040AHG March 2008 Brooks 1110 and 1140 Series THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Page 34: ...the world ensuring quick delivery from local stock timely repairs and locally based sales and service facilities Our dedicated flow experts provide consultation and support assuring successful applic...

Reviews: