background image

Content

Section 1 Introduction

 Introduction......................................................................................................................................1

Intended Use ...................................................................................................................................2

Notice and Caution Statements.......................................................................................................2

Product Description Code ...............................................................................................................2

SolidSense II Pressure Transducer Specifications

..........................................................................5

Section 2 Installation

 General............................................................................................................................................

16

Receipt of Equipment ......................................................................................................................

16

Recommended Storage Practice ....................................................................................................

16

Return Shipment .............................................................................................................................

16

Transit Precautions .........................................................................................................................

17

Removal from Storage ....................................................................................................................

17

Mechanical Connections .................................................................................................................

17

Electrical Connections .....................................................................................................................

18

Installation Instructions - Non-Incendive Field Wiring .....................................................................2

1

Non-Incendive Field Wiring 4-20 mA .................................................................................

......

........2

1

Non-Incendive Field Wiring 0-5 Vdc .......................................................................................

......

...2

2

Zero Adjustment .......................................................................................................................

.

......2

3

Zero 

Adjustment (SolidSense II Standard Pressure Transducers) .................................................

23

Zero Adjustment (ATEX SolidSense II Standard Pressure Transmitters Only) ......................

.

........2

4

Integrated Display Operation..................................................................................................

..

.......2

4

Appendix A: Essential Instructions

 ............................................................................................................ A-1

Warranty, Local Sales/Service Contact Information

 

........................................................................

Back Cover

Summary of Contents for SolidSense II Series

Page 1: ...Installation Operation Manual SolidSense II Series Pressure Transducer...

Page 2: ...r electrical and pressure sources Operation 1 Slowly initiate flow into the system Open process valves slowly to avoid flow surges 2 Check for leaks around the flow meter inlet and outlet connections...

Page 3: ...s 17 Removal from Storage 17 Mechanical Connections 17 Electrical Connections 18 Installation Instructions Non Incendive Field Wiring 21 Non Incendive Field Wiring 4 20 mA 21 Non Incendive Field Wirin...

Page 4: ...lidSense II Series 4A Micro Fit Tee 3 8 Branch X 1 4 Run 12 1 13 Dimensional Drawings SolidSense II Series VM Face Seal Fixed Male 12 1 14 Dimensional Drawings SolidSense II Series Single End GID and...

Page 5: ...ranty information This manual is organized into the following sections Section 1 Introduction Section 2 Installation Section A Essential Instructions Back Cover Limited Warranty and Contacts It is rec...

Page 6: ...t A WARNING statement indicates a potentially hazardous situation which if not avoided could result in death or serious injury A CAUTION statement indicates a potentially hazardous situation which if...

Page 7: ...d D Sub Connector Voltage Output Only x x x x G G G G G 4ft Pigtail with AMP Connector 4 pin Voltage Output Only x x H H H H H 6 inch Pigtail with Molex Connector x x K K K K K 9 pin D Sub Voltage Out...

Page 8: ...IV IV IV Pressure Reference A A A A A Absolute psi C C C C C Compound psi G G G G G Gauge psi B B B B B Absolute Bar P P P P P Compound Bar S S S S S Gauge Bar T T T T T Torr V V V V V Output 4 4 4 4...

Page 9: ...Stainless steel polymer plastics Wetted Parts VIM VAR 316L stainless steel SEMI F20 Surface Finish Compliant with SEMI F19 Cleanliness Compliant to ASTM F1374 92 2005 Internal Volume 1 79cc Process Co...

Page 10: ...for kPa Character Size N A 0 30 height kPa psi Switch N A Yes Rotatable N A Continuous rotation covering 4 quadrants Zero Pot N A Yes Zero Pot Adj Screwdriver N A 1 1 2 mm flat type Approvals and Com...

Page 11: ...ure 1 3 Dimensional Drawings SolidSense II Series SM Face Seal Swivel Male Figure 1 2 Dimensional Drawings SolidSense II Series SC Surface Mount 1 5 C Seal GFD Configurations SolidSense II Series Pres...

Page 12: ...1 5 Dimensional Drawings SolidSense II Series SF Face Seal Swivel VCR Female Figure 1 4 Dimensional Drawings SolidSense II Series CS Surface Mount 1 125 C Seal GFD Configurations SolidSense II Series...

Page 13: ...igure 1 7 Dimensional Drawings SolidSense II Series 4S Tube Weld Stub 1 4 OD Figure 1 6 Dimensional Drawings SolidSense II Series CH 1 5 C Seal High Flow GFD Configurations SolidSense II Series Pressu...

Page 14: ...1 9 Dimensional Drawings SolidSense II Series NT 1 4 Male NPT Figure 1 8 Dimensional Drawings SolidSense II Series CD Surface Mount Longer Gland 1 125 C Seal GFD Configurations SolidSense II Series P...

Page 15: ...11 Dimensional Drawings SolidSense II Series VS Face Seal Fixed Male Swivel Female Figure 1 10 Dimensional Drawings SolidSense II Series SM Face Seal Swivel Male GFF Configurations SolidSense II Serie...

Page 16: ...13 Dimensional Drawings SolidSense II Series VM Face Seal Fixed Male Figure 1 12 Dimensional Drawings SolidSense II Series 4A Micro Fit Tee 3 8 Branch X 1 4 Run GFF Configurations SolidSense II Series...

Page 17: ...uction Figure 1 14 Dimensional Drawings SolidSense II Series Single End GID and Flow Through GIF Integrated Display Models GID GIF Integrated Display Configurations SolidSense II Series Pressure Trans...

Page 18: ...com Products for the data sheet DS PR SolidSense II ATEX PT eng or contact your nearest Brooks Customer Service Center for assistance Note Bendix 15 pin and pigtail available on all ATEX process fitti...

Page 19: ...ect for damaged or missing parts Recommended Storage Practice If intermediate or long term storage of equipment is required it is recommended that the equipment be stored in accordance with the follow...

Page 20: ...re in a clean environment a Remove the pressure transducer from the box and carry it into the gray area b Remove the outer protective bag and discard c Carry the pressure transducer sealed in inner ba...

Page 21: ...ams are shown in Figures 2 1 through 2 6 Connect the cable braid and drain wire to an earth ground to help reduce inductive signal interference Table 2 1 specifies the minimum resistance for the outpu...

Page 22: ...2 Voltage Output Pinouts Figure 2 1 4 20 mA Pinouts Pigtail Pigtail 15 Pin HD D Sub 15 Pin HD D Sub Bendix Bendix 3 1 3 1 66 10 17 287387 1 1 7 7 21 1 1 1 287387 7 7 21 9 Pin D Sub SolidSense II Serie...

Page 23: ...r can be wired directly to a 12 or 24 Vdc LR056 The pigtail cable is connected as shown in Figure 2 3a Figure 2 3a 4 20 mA Output Device Wiring to LR056 Figure 2 3b Integrated Display Electrical Conne...

Page 24: ...ing apparatus with associated non incendive field wiring apparatus using any of the wiring methods permitted for unclassified loca tions 2 Vmax Voc or Vt Ca Ci C cable La Li L cable 3 For this current...

Page 25: ...ted non incendive field wiring apparatus using any of the wiring methods permitted for unclassified locations 2 Vmax Voc or Vt Ca Ci C cable La Li L cable 3 For this current controlled curcuit the par...

Page 26: ...crew on the Standard SolidSense II Pressure Tranducers Red Excitation Black Common Bare Drain Wire Zero Adjustment Screw Zero Adjustment The SolidSense II pressure transducer is factory calibrated and...

Page 27: ...o Adjustment Screw Tighten the VCR nut with a wrench an additional 1 8 turn if using SST or nickel seals or 1 4 turn is using copper seal Do not use the device housing access cover nut ATEX devices or...

Page 28: ...djust On the Integrated Display SolidSense II transmitters the zero adjust screw is located on the top face adjacent to the display switch as noted in Figure 2 8 Display Rotation Rotate Display by han...

Page 29: ...ERVICE AND IN SITU CALIBRATION Brooks Instrument can provide start up service prior to operation when required For some process applications where ISO 9001 Quality Certification is important it is man...

Reviews: