22
GENERAL OPERATING INFORMATION
Rated Capacity
3,500 gal. for Aesthetic Chlorine / 243 gal. for VOC’s
Min-Max operating pressure:
40psi-120psi (275Kpa-827Kpa)
Min-Max feed water temperature:
41°F – 95°F (5°C – 35°C)
Rated Service Flow
0.07 gallons per minute
Daily Water Production Rate
56.9 gallons per day
Product Efficiency Rating
30.6%
•
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
•
Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
•
The influent water to the system shall include the following characteristics:
•
No organic solvents
•
Chlorine: < 2 mg/L
•
pH: 7 - 8
•
Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
•
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
•
Iron: < 2 mg/L
•
Turbidity: < 1 NTU
•
Hardness: < 1 000 mg/L
Substance
Influent Challenge
Concentration
(mg/L unless specified)
Maximum Allowable Product
Water Concentration
(mg/L unless specified)
Percent Reduction
(%)
Arsenic (Pentavalent)
0.05 +/- 10%
0.01
98.9
Barium
10.0 +/- 10%
2
98.2
Radium 226/228
25 pCi/L
5 pCi/L
80
Cadmium
0.03 +/- 10%
0.005
98.2
Chromium (Hexavalent)
0.3 +/- 10%
0.1
97.3
Chromium (Trivalent)
0.3 +/- 10%
0.1
97.8
Copper
3.0 +/- 10%
1.3
98.7
Lead
0.15 +/- 10%
0.01
98.2
Selenium
0.10 +/- 10%
0.05
97.3
Fluoride
8.0 +/- 10%
1.5
83.8
TDS
750 +/- 40
187
92.5
Aesthetic Chlorine
2.0 +/- 10 %
>/= 50% Reduction
98.4
VOCs
0.300 +/- 10%
>/= 95% Reduction
99.8
While testing was performed under laboratory conditions, actual performance may vary.
The RC100 is tested and certified to NSF/ANSI 42, 53 and 58 for the reduction of Aesthetic Chlorine,
Taste and Odor, Cyst*, VOCs, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium,
Hexavalent Chromium, Trivalent Chromium, Lead, Copper, Selenium and TDS as verified and
substantiated by test data. The RC100 conforms to NSF/ANSI 372 for low lead compliance.
*NSF/ANSI 58 Cyst reduction of 99.9% based on independent testing not certified by WQA.
This system has been tested according to NSF/ANSI 42, 53 and 58 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible for water leaving the system, as
specified in NSF/ANSI 42, 53 and 58.
CIRCLE FILTRATION SYSTEM PERFORMANCE DATA SHEET
Model: RC100
Summary of Contents for RC100
Page 1: ...OWNER S MANUAL Circle Reverse Osmosis Water Filtration System Model RC100 ...
Page 2: ......
Page 29: ...27 NOTES ...
Page 30: ...MANUAL DE USUARIO Sistema Circle para Filtrado de Agua por Ósmosis Inversa Modelo RC100 ...
Page 31: ...29 ...
Page 58: ...NOTAS 56 ...
Page 59: ...MANUEL DE L UTILISATEUR Système de filtration d eau à osmose inverse Circle N de modèle RC100 ...
Page 60: ...58 ...
Page 87: ...85 NOTES ...
Page 88: ......