Bron D 1600 Operating Instructions Manual Download Page 5

6

 

  

ATTENTION! IMPORTANT SAFETY INSTRUCTIONS

 

 

  D 1600 | EB 800.1600

 

>     Read carefully before starting up!

 

>    The equipment should be used exclusively by qualified personnel.

 

>    Use only a complete and undamaged connection cable. Position the cable so that it will not be 

tripped over or make contact with hot surfaces. If an extension cable is necessary, ensure that a 
cable is used with a current rating at least equal to that of the ballast. Cables rated for less amper-
age than the appliance may overheat.

 

>   For safety reasons, the ballast unit may only be operated with an earthed mains (AC-line) plug.  

 

  When the appliance is switched on, the yellow LED light must illuminate.

 

>   Avoid incorrect use of any kind and be particularly careful not to obstruct the natural circulation of  

 

  air that keeps the lamp and ballast unit cool.

 

>   The ballast unit and lamp must not be exposed to moisture. This could cause dangerous electric  

 

  discharges on contact!

 

>   To minimise the risk of fire, electric shock, or injury to persons, use exclusively accessories  

 

  recommended by the manufacturer.

 

>   The equipment must not be used in explosion-hazard areas.

 

>   The lamp and accessory attachments may heat up to high temperatures. Please handle with care.

 

>   When these units are used suspended, they must always be secured with a steel cable.

 

>   To protect against the effects of radiated heat, the lamp must not be directed at flammable  

 

  surfaces and/or surfaces sensitive to heat or any objects from less than a minimum distance of  

 

  2 meters.

 

>   In order to achieve maximum service life from the lamp, the heating up process of approx.  

 

  1 minute should not be interrupted.

 

>   Use the lamp only with a reflector or adapter with undamaged safety glass. Lamps can burst.  

 

  The safety glass will retain hot fragments.

 

>   Like natural daylight, HMI/MSR light contains a certain proportion of UV radiation. The safety glass  

 

  reduces the UV content to safe levels for normal operating distances. When used at a close  

 

  operating distance, limit the exposure time of unprotected skin. 

 

>   Before replacing fuses or the lamp, disconnect the ballast unit from the mains power supply.

 

>   Before the ballast unit is cleaned or serviced, and while it is not in use, it must be switched off  

 

  and completely disconnected from the mains supply. Never pull on the cable itself: pull only on the  

 

  plug body.

 

>   Allow time for the ballast unit and lamp to cool before you stow them.

 

>   Units with noticeable damage or which have been dropped must not be started up. Contact a  

 

  broncolor service station. Service work or repairs must always be carried out by a specialist.

  >   Only original spare parts must be used to guarantee long-term mechanical and electrical  
 

  operating safety. Incorrect assembly can cause dangerous contact voltages, even on connected  

 

 units.

Summary of Contents for D 1600

Page 1: ...Operating instructions Bedienungsanleitung Mode d emploi D 1600 EB 800 1600...

Page 2: ......

Page 3: ......

Page 4: ...Starting up 7 2 Fitting or changing a bulb 8 3 Mounting and removing reflectors and adapters 8 4 Fitting and removing accessories 8 5 Focusing 9 6 Operating the lamp with a Para 9 7 Operating modes 9...

Page 5: ...th a steel cable To protect against the effects of radiated heat the lamp must not be directed at flammable surfaces and or surfaces sensitive to heat or any objects from less than a minimum distance...

Page 6: ...ins and check the earth conductor Step 3 Operate switch 9 on the lamp and press button 4 on the ballast unit The bulb fires and starts operating By operating the switch 9 on the lamp or on the ballast...

Page 7: ...ar the security pin 16 latch Take care not to damage the bulb while dismounting an accessory Removing Loosen the retaining screw 10 on the lamp then pull it straight backwards and hold it Turn the ref...

Page 8: ...It is recommended that the lamp s yoke 21 is removed completely To remove it undo the screws 18 and pull the two carrier plates with the yoke towards the handle The complete yoke can now be removed P...

Page 9: ...s to indicate this Low voltage protection If the applied voltage is below 90 V the ballast unit either switches off automatically or cannot be switched on Button 4 blinks to indicate this Current limi...

Page 10: ...n on More than 10 ignition attempts Allow to cool blinks off blinks blinks on on on Technical fault Service station blinks blinks blinks blinks blinks blinks on 10 FAULT DIAGNOSIS TABLE Ballast units...

Page 11: ...mp has been identified 8 Rotary knob for adjusting output dimmer 13 TECHNICAL DATA BALLAST UNIT EB 800 1600 Supply power rating 1800 VA Mains voltage 90 265 V Mains frequency 50 60 Hz Current draw 20...

Page 12: ...13...

Page 13: ...e for yoke 20 Slots for reflector or Softbox adapter 21 Yoke 22 28 mm 1 1 stand spigot with 16 mm 0 6 bore 23 Retaining screw 24 PAR reflector 25 Diffusion lens 26 Scrim ring 27 Four leaf barn door fo...

Page 14: ...15...

Page 15: ...0713 Fresnel lens 713 0534 Bag for 5 filters or lenses 763 0322 1600 W bulb G E CSR1600 SE HR UVC 633 7410 1600 W bulb Sylvania BA1600 SE HR UVC 633 7411 Lamp cable 7 5 m 742 0599 Lamp cable 10 m 742...