background image

4 | 

P a g e      

 

R e v 4 . 1

 

 

 
 
 

1. 

Remove all the packing materials from the appliance before connecting the gas

 

 

2.  Appliance Gas inlet fitting located at the rear of the appliance: ¼ ” BSPM for Natural Gas and for LP Gas, 5/8-18 

UNF thread (known as 3/8 SAE male fitting).   

 

3. 

Ensure that the gas supply connection point is accessible when the appliance is installed

 

4. 

For Natural Gas (NG) Models:

 

 

The appliance is supplied with an approved regulator & must be installed in accordance with AS/NZS 5601.1 by 
an authorised gas fitter / plumber. The connecting hose must be an approved type. The connection of hose to 
the gas supply must provide a secure connection free of gas leakage. The hose should not be subjected to 
abrasion, kinking or permanent deformation and should be able to be inspected along its entire length with the 
appliance in the installed position

For gas supply pressure see technical specification on page10 

 

Fix the appliance onto the bench by drilling holes into the bench top to the position of the fixing brackets. Place 
brackets into position on the appliance over the burner support beam and screw into position using the supplied 
screws. Screw the brackets securely to the bench top using the appropriate nut and screws 
 
Check for gas leakage at all joints with soapy water or other approved methods 

 

 

For LP Gas Models

 

Where the LPG models are connected to a permanently fixed reticulated LP Gas supply, they must be installed 
in accordance with AS/NZS 5601.1 by an authorised gas fitter / plumber

.  

 

Where  the  LPG  models  are  used  in  quasi-outdoor/indoor  areas  such  as  an  alfresco  or  balcony  situation  the 
purchaser (consumer) may use an approved (certified) LP Gas regulator and hose assembly connected to a 4.5 
or 9.0kg LP Gas cylinder.  
 
Note:  a certified hose LPG gas regulator and hose assembly is one that where  LP regulator fitted with a POL 
type inlet fitting, outlet pressure of 2.75kPa and Certified to AS4621 and an 8mm nominal bore hose (maximum 
length 1.5 metres) certified to AS/NZS 1869 
 
The use of 4.5 or 9.0kg LP Gas cylinders inside a building should be avoided.  

 

Fix the appliance onto the bench by drilling holes into the bench top to the position of the fixing brackets. Place 
brackets into position on the appliance over the burner support beam and screw into position using the supplied 
screws. Screw the brackets securely to the bench top using the appropriate nut and screws 
 
Check for gas leakage at all joints with soapy water or other approved methods 

 

UNDER NO CIRCUMSTANCES SHOULD A NAKED FLAME BE USED IN CHECKING 

FOR GAS LEAKS. 

 

 

PRESSURE ADJUSTMENT OF THE REGULATORS 

 

Never adjust the pressure of the regulators. The natural gas regulator is already adjusted to the correct pressure of 

1.0kPa. 
 

 

If you suspect the pressure of the regulator is abnormal, please contact Bromic Pty Ltd for assistance. 

 

 

 

 

 

 

Summary of Contents for DC100-S

Page 1: ...ory regulation s Refer to AS NZS 5601 1 for piping size details GAS PRESSURE REGULATOR DETAILS FOR NG MODELS The NG model they must be installed in accordance with AS NZS 5601 1 by an authorised gas fitter plumber A natural gas regulator Maxitrol RV20LM AGA Approval No 3088 with an outlet pressure of 1 0kPa is included with this appliance FOR LP MODELS Where the LPG models are connected to a perma...

Page 2: ...e and its effect on surrounding surfaces clothing and skin Children or the elderly should be supervised when near this appliance Do not hang clothing or other flammable material on or near this appliance Always keep flammable materials away from the appliance Make sure that you use cooking woks pots or pans that sit firmly on the trivet Do not use pots that are too small large for the burner size ...

Page 3: ...aximum performance economy and safety of operation Always ensure that adequate fresh air is provided for ventilation The minimum volume of the room where appliance is installed 1 5 M2 per MJ Refer to AS NZS 5601 1 for details of the necessary ventilation requirements including the size of the openings The appliance must only be operated on a level firm non combustible surface This appliance shall ...

Page 4: ... LP Gas Models Where the LPG models are connected to a permanently fixed reticulated LP Gas supply they must be installed in accordance with AS NZS 5601 1 by an authorised gas fitter plumber Where the LPG models are used in quasi outdoor indoor areas such as an alfresco or balcony situation the purchaser consumer may use an approved certified LP Gas regulator and hose assembly connected to a 4 5 o...

Page 5: ...e is off 7 The consumer fully understands the safety precautions operation and maintenance 8 The operation of the ignition system is satisfactory 9 The operation of the flame thermocouple safeguard is satisfactory 10 Flame abnormalities If any of the following are observed during operation of the appliance Carbon build up on the appliance or pans Excessive yellow tipping of the burner flame flames...

Page 6: ...s time press and hold the control knob for longer up to 10 seconds Warning Risk of deflagration 3 If after 10 seconds the flame does not ignite switch off the burner and open a nearby window or door Wait at least one minute before trying to switch the burner back again If the flame still does not ignite contact Bromic Pty Ltd or an authorized agent for assistance 4 Flame abnormalities If any of th...

Page 7: ...pan over the burner not to one side Otherwise it could tip over Place the pans on the pan supports never directly on the burner Make sure that the pan supports and burner caps are correctly positioned before using the appliance Pans should be placed on the hob carefully Do not strike the hob and do not place excessive weight on it CAUTION CORRECT PLACEMENT OF UTENSILS DO NOT SPRAY AEROSOLS IN THE ...

Page 8: ... clean these areas with a product that is suitable for stainless steel SERVICE INSTRUCTIONS FOR AUTHORISED PERSON such as LICENSED GAS FITTER OR PLUMBER DO NOT MODIFY THIS APPLAINCE Access to components under the hob Ensure the appliance is cool before attempting any service and the gas supply is turned off or disconnected Disconnect regulator or hose from gas supply Remove trivet s spillage bowls...

Page 9: ... 56 mm x 2 openings Primary air shutter in fully open position LP Gas Main burner inner primary aeration control 12 14 mm x 2 openings Primary air shutter in fully open position TROUBLESHOOTING Problem Possible Cause Solution No Ignition Main Gas Valve is not turned on Air trapped in the gas hose Electronic ignition is wet or dirty The safety valve is not open Turn off the gas valve once and then ...

Page 10: ...50 0 68 Dimensions mm H 145x W 300x D 382 H 145x W 720x D 382 Net Weight kg 3 7 6 6 Gas Type UNIVERSL LP GAS Gas Pressure kPa 2 75 Gas Fitting 5 8 18 UNF thread known as 3 8 SAE male fitting Ignition System Piezo electric Country of Origin China AGA Approval No 7092 G Bromic Pty Ltd and their appointed agents will not be liable in respect of any misuse which is not in accordance with the instructi...

Page 11: ...e the Purchaser for any investigation or service including parts and labour which is found not to be connected to a warranty issue Bromic is not liable for any incidental or consequential loss or damage arising from any cause whatsoever including but not limited to loss or damage arising from misuse of the Ring Burner neglect accident improper installation unauthorised modification unauthorised at...

Page 12: ...12 P a g e R e v 4 1 Call 1300 276 642 1300 BROMIC or 61 2 9426 5222 Email us plumbing bromic com au Visit www bromic com plumbing ...

Reviews: