Appendix
A-4
Environmental Specifications
The SilkWorm 2400 switch’s primary operating environments are server rooms, network
equipment closets, and office environments. The acceptable environmental ranges for a
SilkWorm switch are shown in Table A-4:
Dimensions
The switch may be configured for either rack mount or tabletop use.
Rack Mount Dimensions
1U, 19-in. rack mount (EIA compliant)
H: mm (1.71 in.), W: 428.6 mm (16.88 in.), D: 450.0 mm (17.72 in.)
Table Top Dimensions
H: 43.4 mm (1.86 in.), W: 428.6 mm (16.88 in.), D: 450.0 mm (17.72 in.)
Weight
17 lbs.
Table A-4
SilkWorm 2400 Environmental Specifications
Specification
Value
Temperature (operating)
0
°
C to 40
°
C
Temperature (non-operating)
-35
°
C to 65
°
C
Operating humidity
5% to 85% noncondensing @ 40
°
C
Nonoperating humidity
95% RH noncondensing @ 40
°
C
Operating Altitude
0 to 3 kilometers above sea level
Nonoperating Altitude
0 to 12 kilometers above sea level
Operating shock
5g, 11MS duration, half sine
Nonoperating shock
20g, 11MS duration, sq.wave
Operating vibration
5, [email protected] octave/minute
Nonoperating vibration
10, [email protected] octave/minute
Handling drop
Summary of Contents for SilkWorm 2400