Chapter 2 Installation
2-6
Standalone
The switch is shipped in its standalone configuration. Adhesive rubber feet are supplied
if the switch is surface mounted. Rubber feet installation is required for proper or safe
switch operation.
To install the adhesive rubber feet:
1
Clean the four depressions at each corner of the chassis bottom so that they are free
of dust.
2
Remove the rubber feet from the sheet and place one in each depression.
3
Firmly press the rubber feet in place.
Fiber Channel Cable Connections
All network cable connections are to the switch’s front panel. All recommended cabling
supports the switch’s 1.0625-Gbps transfer rate, as shown in Table 2-1.
NOTE:
The switch is not designed to interoperate with devices using
an Open Fibre Control optical interface.
Table 2-1
Cabling Connections
C
ABLE
TYPE
C
ABLE
S
PECIFICATION
M
AXIMUM
RUN
LENGTH
GBIC
MODULE
OPTICAL
WAVELENGTH
SWL Fiber
Optic
a
a. Recommend using a low EMI optical cable design.
• Duplex SC plug
connectors
• Multimode fiber
• 50
µ
m core diameter
• 125
µ
m cladding diameter
duplex cable
• 500
meters
• 1641 feet
780-860
µ
m
without open
fiber control
(non-OFC)
LWL Fiber
Optic
a
• Duplex SC plug
connectors
• Single mode fiber
• 9
µ
m core diameter
• 125
µ
m cladding diameter
duplex cable
• 10
Kilometers
• 84480 feet
1270-1350
µ
m
without open
fiber control
(non-OFC)
Copper
• Impedance controlled for
150 ohm differential
systems
• Low skew, shielded quad,
150 ohm cable
• Polarized interface
• HSSDC receptacle
• 13 meters
• 42 feet
NA