background image

1-2

SilkWorm 2100 Reference

Overview

1

The SilkWorm 2100 Advantage

The SilkWorm 2100 switch offers advantages in the following areas:

Performance

Reliability

Manageability

Flexibility

Performance

The SilkWorm 2100 switch offers enhanced performance:

Data Transfer

A device arbitrates only among the devices in its looplet; frames are 
transferred to the switch for forwarding to a destination device on 
another looplet.

The non-blocking architecture of the SilkWorm 2100 switch 
guarantees full-speed data delivery in all traffic conditions. 
Cut-through routing ensures a maximum latency of 2 microseconds 
from switch port to switch port, allowing parallel data transfers of 
up to eight (one per loop) simultaneous transactions at a time. 
Whereas traditional hub-based arbitrated loops are limited to a total 
shared bandwidth of 100 MB/sec, the SilkWorm 2100 switch is 
capable of transferring data at eight times (800 MB/sec) that rate.

Buffering

Unlike a traditional loop environment where a device is blocked 
from transferring data when another device on the loop has control, 
the SilkWorm 2100 switch can buffer data within the switch 
allowing a device to transfer multiple frames. This allows for 
overlapping transfers and improves the overall throughput of 
the SAN.

Reliability

The SilkWorm 2100 switch provides enhanced reliability:

Port Isolation

The SilkWorm 2100 switch monitors each looplet to ensure proper 
device operation. If errors are detected the looplet is not allowed to 
initialize and the port is taken out of service. An alert is generated 
and the port is monitored until the error condition is cleared. This 
enables the loop to operate while the device is isolated and repaired, 
thereby preventing a failing device from disabling the entire loop.

Status Reporting

The SilkWorm 2100 switch provides extensive statistics, including 
a full set of performance and error counters, to aid in diagnosis and 
isolation of malfunctioning ports. These statistics are retrieved via 
several interfaces such as SNMP, telnet, and an optional Web-based 
management interface feature, WEB TOOLS.

Diagnostics

Power On Self Tests (POSTs) and online diagnostics monitor 
individual ports while the switch is running. Offline diagnostics 
isolate problems enabling faster restoration of service.

Hardware Features Redundant fans and a hot-pluggable redundant power supply 

option eliminate service down time related to failing power 
supplies or fans. 

Summary of Contents for SilkWorm 2100

Page 1: ...53 0001507 01 SilkWorm 2100 Reference...

Page 2: ...e or may be trademarks or service marks of and are used to identify products or services of their respective owners Notice This document is for informational purposes only and does not set forth any w...

Page 3: ...ions Japanese Text CE Statement The standards compliance label on the SilkWorm 2100 Fibre Channel Switch contains the CE mark which indicates that this system conforms to the provisions of the followi...

Page 4: ...iv SilkWorm 2100 Reference Notices...

Page 5: ...1 4 Main Board 1 4 Fabric OS 1 4 GBIC Modules 1 4 The SilkWorm 2100 Switch and Fabric OS 1 6 Chapter 2 Setup and Installation Choose an Appropriate Location 2 1 Provide Cooling Air and Power Sources...

Page 6: ...vi SilkWorm 2100 Reference Appendix A Specifications General A 1 Safety A 2 Optical Port A 3 Copper GBIC Module A 3 Environmental A 3 Dimensions A 4 Power Supply A 4 Index...

Page 7: ...tion on Fibre Channel and Fibre Channel standards This web site is located at http www fibrechannel com Preface Provides information on related publications available training getting help and getting...

Page 8: ...formed Getting Software Updates Your switch supplier is also your source for obtaining software updates and maintenance releases Contact your supplier to obtain information on available maintenance re...

Page 9: ...connected to form an FC AL When a loop is formed a Loop Initialization Protocol LIP initializes all the devices on each looplet When the LIP sequence completes a virtual arbitrated loop is formed fro...

Page 10: ...ithin the switch allowing a device to transfer multiple frames This allows for overlapping transfers and improves the overall throughput of the SAN Reliability The SilkWorm 2100 switch provides enhanc...

Page 11: ...a potential problem limits network downtime Error logs record specific trouble areas or devices facilitating fault isolation Flexibility The SilkWorm 2100 switch provides enhanced flexibility Investm...

Page 12: ...ions are protected by a metal spring loaded door The main board module is structured to accommodate a universal port The universal port U port supports attachment to the NL_port devices associated wit...

Page 13: ...ace if no fiber optic cable is connected to the port An LWL fiber optic GBIC module is shown in Figure 1 2 Figure 1 2 Long Wavelength Laser LWL fiber optic GBIC module Passive Copper GBIC Module The C...

Page 14: ...in all switch environments in the SilkWorm 2000 family below are specific limitations when Fabric OS is implemented in the non fabric enabled environment of the SilkWorm 2100 switch licenseShow comman...

Page 15: ...tail in the following sections Choose an Appropriate Location Install the SilkWorm 2100 switch in a secure or limited access area so that access to cable and power connections is controlled For easy a...

Page 16: ...ided and are required for safe operation To install the adhesive rubber feet 1 Ensure the depressions at each corner of the chassis bottom are clean and free of dust 2 Firmly press one rubber foot int...

Page 17: ...the switch using the screws supplied Note In order for the slides to work properly all mounting screws must be inserted with the screw heads inside the slides Do not use washers 3 Attach the outer sli...

Page 18: ...Type Cable Specification Maximum Run Length Minimum Bend Radius GBIC Module Optical Wavelength SWL Fibre Optic Duplex SC plug connectors Multimode fiber 50 m core diameter 125 m cladding diameter dup...

Page 19: ...gular maintenance Remove the serial port cable and cover the port during normal operation of the switch A cover is included with the switch Only one command session can be active at a time and because...

Page 20: ...address Ethernet subnetmask and gateway address For detailed information on this command see the Fabric OS manual 4 Write the IP address on the label on the top of the front panel of the switch to fa...

Page 21: ...est Port Register Test Central Memory Test CMI Conn Test CAM Test Port Loopback Test As each test is performed a Passed message is displayed If a malfunction occurs during POST error messages are writ...

Page 22: ...2 8 SilkWorm 2100 Reference Setup and Installation 2...

Page 23: ...e the tests available along with the command to initiate each they are run from the local telnet port See Fabric OS Chapter 4 Diagnostics for detailed information on commands Table 3 1 Diagnostic Test...

Page 24: ...ndix C Error Messages for a detailed description of each message Port Loopback Test portLoopbackTest Checks all switch main board hardware Frames transmitted are looped back and received Run offline C...

Page 25: ...y yellow Receiving light or signal carrier but not yet online Slow yellow disabled result of diagnostics or port Disable command Flashes every 2 seconds Fast yellow Error fault with port Flashes every...

Page 26: ...3 4 SilkWorm 2100 Reference Diagnostics 3...

Page 27: ...mber of Fibre Channel ports 8 ports Fibre Channel port speed 1 0625 Gbps full duplex Modes of operation Fibre Channel Class 2 service and Fibre Channel Class 3 connectionless service Aggregate switch...

Page 28: ...vel A 89 336 EEC Norway EN60950 A1 A2 A3 A4 A11 Finland EN60950 A1 A2 A3 A4 A11 73 23 EEC EN55022 Level A 89 336 EEC France EN60950 A1 A2 A3 A4 A11 73 23 EEC EN55022 Level A 89 336 EEC Germany EN60950...

Page 29: ...up to 13 meters have currently been qualified thereby supporting ANSI X3 230 FC PH intra cabinet requirements Standard cables with HSSDC to DB9 male connectors can also be used Environmental The SilkW...

Page 30: ...ter and power indicator The power supply meets the requirements in Table A 5 Rack Mount Dimensions 1U 19 in rack mount EIA compliant H 43 4 mm 1 71 in W 428 6 mm 16 88 in D 450 0 mm 17 72 in Desk Top...

Page 31: ...A 3 LWL Fiber Optic 1 5 Passive Copper 1 5 SWL Fiber Optic 1 4 H Hardware Features 1 2 I initialization 2 7 Investment Protection 1 3 L licenseShow 1 6 Loop Initialization Protocol LIP 1 1 M Main Boa...

Page 32: ...Index Index 2 SilkWorm 2100 Reference...

Reviews: