MODELS QTXE050 • QTXE080 • QTXE110
TYPICAL INSTALLATIONS
Housing mounted to
I
-joists.
Housing mounted
anywhere between
trusses using hang-
er bars.
Housing mounted any-
where between
I
-joists
using
hanger bars.
Housing mounted to
joists.
Housing mounted
anywhere between
joists
using
hanger bars.
Housing mounted
anywhere between
trusses using hang-
er bars.
PLAN THE INSTALLATION
The ducting from this fan to the outside of the building has a strong
effect on the air flow, noise and energy use of the fan. Use the
shortest, straightest duct routing possible for best performance,
and avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may not achieve
their rated airflow.
Use a roof cap or wall cap that has a built-in damper to reduce
backdrafts.
Plan to supply the unit with proper line voltage and appropriate
power cable.
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
POWER
CABLE*
6-IN. ROUND
DUCT*
6-IN.
ROUND
ELBOWS*
Seal gaps
around
Housing.
Seal duct
joints with
tape.
OR
Keep duct
runs short.
WALL CAP*
(with built-in
damper)