background image

RB80LC 

„

 

RB110LC Installation Guide

Page 3

1

2

3

4

Parts Bag holds 
 Knockout Plate 
 and six (6)  screws

Remove
Instruction
Sheet

Punch out Mask from

packaging. See Step 6.

New Construction Installation

Tools needed

• Power screwdriver with a Phillips bit

• Phillips screwdriver

• Flathead screwdriver

• Pliers

•  Wire insulation stripper

• Wire cutter

Materials needed

•  4" round metal ducting recommended for best performance

  Use of other ducting is acceptable but may impact performance

•  Roof cap or wall cap (built-in damper recommended)

•  Tape to seal duct connections

•  Electrical wiring and supplies per local code requirements 

•  4W (max.) C7-type night light bulb

1

 Remove Packaging

2

 Install

 Mounting
 Frame

Remove CFL Bulbs 

from protective packaging.

Summary of Contents for ULTRA Pro RB110LC

Page 1: ...ion and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 13 Service Parts 13 Warranty 14 2014 Broan NuTone LLC RB80LC RB110LC ULTRA ProTM Ventilation Fan Light Night Light with ULTRAQuickTM Installation Technology INSTALLATION GUIDE ...

Page 2: ...r hidden utilities 6 Ducted fans must always be vented to the outdoors 7 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 Use an on off switch to operate this ventilator Use of speed controls may cause a motor humming noise 9 This unit must be grounded Typ...

Page 3: ...river Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 4 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Electrical wiring and supplies per local code requirements 4W max C7 type night light bulb 1 Remove Packaging 2 Inst...

Page 4: ...lange Transition and Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing Insert tab into slot inside Housing Screw from Parts Bag Flange Tape Tape 4 Ducting snap Transition Align ...

Page 5: ... to operate the light Screw from Parts Bag Attach cable clamp to Knockout Plate Knockout Plate mounts to outside of Housing and may be oriented as desired Connect wires LINE IN GRD WHT BLK GRD WHT WHT WHT WHT WHT BLK BLK RED BLU RED BLK LIGHT SWITCH NIGHT LIGHT SWITCH FAN SWITCH FAN LIGHT NIGHT LIGHT FAN RECEPTACLE LIGHT RECEPTACLE LIGHT RECEPTACLE WIRES MULTI CONTROL purchase separately 120 VAC L...

Page 6: ...rt Mask and Finish Ceiling 7 Install Grille See Page 12 for Operation Cleaning and Maintenance See Page 13 for Troubleshooting Mask protects unit during construction Remove before installing Grille Install ceiling material Cut out around Housing 8 Install Bulbs Night Light purchase separately ...

Page 7: ... damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from packaging See Step 12 1 Remove Packaging 2 Switch Off Power 4 Examine Wiring 3 Enlarge Ceiling Opening and Remove Existing Fan Ruler Pencil Drywall saw Claw hammer or pry bar Utility knife Materials needed Tape to seal duct connections Ex...

Page 8: ...3 4 5 1 2 3 2 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Remove screws from Mounting Frame and set aside ...

Page 9: ...rews set aside in Step 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Flange Transition and Ducting 8 Secure Mounting Frame 9 Snap in Housing snap Tape Tape Transition 4 Ducting Flange Align ...

Page 10: ...m Do not use a dimmer switch to operate the light LINE IN GRD WHT BLK GRD WHT WHT WHT WHT WHT BLK BLK RED BLU RED BLK LIGHT SWITCH NIGHT LIGHT SWITCH FAN SWITCH FAN LIGHT NIGHT LIGHT FAN RECEPTACLE LIGHT RECEPTACLE LIGHT RECEPTACLE WIRES MULTI CONTROL purchase separately 120 VAC LINE IN SWITCH BOX LIGHT NIGHT LIGHT FAN UNIT SWITCH BOX BLACK WHITE BLUE GROUND green or bare KNOCKOUT PLATE FAN RECEPT...

Page 11: ...rofit Installation 12 Insert and Secure Blower Assembly 13 Install Grille Screws from Parts Bag If ceiling repairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille ...

Page 12: ... be operated independently using separate on off switches Cleaning and Maintenance To Clean For quiet and efficient operation long life and attractive appearance remove Grille and vacuum interior of unit with a dusting brush attachment The Motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the Motor To change bulbs Refer to R...

Page 13: ...Lens 11 99271381 Bulb GU24 18W 3500K Fluorescent 2 req d Troubleshooting Symptom The fan does not run Check for an open fuse or circuit breaker in the building s service panel Check that the plug in connection for the Motor is seated firmly in place Check that the Blower Wheel spins freely Symptom The fan runs erratically Check that the Blower Wheel is firmly attached to the Motor shaft and both s...

Page 14: ... wear of finish i Fans in commercial or nonresidential use or j damage caused by fire flood or other act of God This warranty covers only Fans sold in Canada or through Canadian distributors authorized by Broan EXCLUSION OF DAMAGES BROAN S OBLIGATION TO PROVIDE REPLACEMENT PARTS OR REPAIR OR REPLACE AT BROAN S OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND BROAN S S...