background image

3

WIRE THE FAN / LIGHT

1. Remove knockout panel and wire unit following appropriate diagram. Run electrical

cable directly to unit. Do not allow cable to touch sides or top of unit after installation
is complete. Push all wiring into corner of unit. Replace knockout panel.

2. Replace blower assembly and secure with screw removed previously. Plug motor

into receptacle.

ATTACH THE
GRILLE 

(CONT'D)

ATTACH THE GRILLE

1. Plug lights into receptacles.

CLEANING

Plastic parts can be cleaned with mild, soapy water. Use a mild
detergent such as dishwashing liquid. Dry with a soft cloth. DO
NOT USE ABRASIVE CLOTH, STEEL WOOL PADS OR SCOUR-
ING POWDERS.

To clean blower assembly: Remove grille, unplug lights and
motor, remove screw and lower blower assembly from housing.
Gently vacuum impeller, motor and interior of housing. METAL
AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN
WATER.

LUBRICATION

Motor is permanently lubricated. No additional lubrication is
necessary.

2. Attach grille assembly with two long screws

(provided). DO NOT OVERTIGHTEN - Dam-
age to grille may result.

3. Install bulbs. See Use and Care instructions

for bulb specifications.

4. Snap light lens into place.

5. Turn on power and check fan and light

operation.

USE AND CARE

DISCONNECT ELECTRIC POWER SUPPLY
AND LOCK OUT SERVICE PANEL BEFORE
CLEANING OR SERVICING THIS UNIT.

BULB REPLACEMENT

Remove light lens by gently pulling down on
one edge.

Use only the following 18 Watt fluorescent
lamps for the primary light and a 7 Watt maxi-
mum incandescent bulb for the night light.

BROAN:  97010730
SYLVANIA:  CF18DD827
PHILLIPS:  PL-C 18W/27
GENERAL ELECTRIC:  F18DBX/T4/SPX27
OSRAM:  CF18DD827
NEMA: Type CFQ18W/G24d

WHITE

BLACK

SWITCH

BOX

RED

120 VAC

LINE IN

LIGHT

NIGHT LIGHT

FAN

THREE-FUNCTION

CONTROL

(purchase separately)

GROUND (bare)

BLUE

KNOCKOUT

PANEL

POWER ENTERING

SWITCH BOX

SWITCH BOX

LIGHT

NIGHT LIGHT

FAN

THREE-FUNCTION

CONTROL

(purchase separately)

YELLOW

WHITE

BLACK

RED

GROUND
(bare)

BLUE

KNOCKOUT

PANEL

120 VAC

LINE IN

POWER ENTERING VENTILATOR

Broan at

::

bathroomsource

.

com

is a division of

kitchen

::

accessories

U      N      L      I      M      I      T      E      D

::

bathroomsource

.

com

                   

Call 1-800-667-8721 anywhere in the US and Canada -

www.bathroomsource.com

Summary of Contents for SOLITAIRE ULTRA-SILENT S110FLUE

Page 1: ...ufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers AS...

Page 2: ...uring guides on corners of housing to check if unit will be flush with finished ceiling Pound nails tight For wide joist centers A 8 x 3 8 self tapping screw can be used to join extended brackets toge...

Page 3: ...ong screws provided DONOTOVERTIGHTEN Dam age to grille may result 3 Install bulbs See Use and Care instructions for bulb specifications 4 Snap light lens into place 5 Turn on power and check fan and l...

Page 4: ...e above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To...

Page 5: ...r donde pueda ser alcanzado desde un ba o o ducha 9 Esta unidad debe ser conectada a tierra PRECAUCION 1 Solamente para uso de ventilaci n general No se use para extraer materiales o vapores peligroso...

Page 6: ...da en las esquinas de la caja para comprobar si la unidad est a nivel con el techo acabado Clave los clavos completamente Para centros de viga anchos se puede usar un tornillo autorroscante 8 x 3 8 pa...

Page 7: ...on una tela suave NO USE TELAS ABRASIVAS ESPONJILLAS DE LANA DE ACERO O POLVOS ABRASIVOS Para limpiar el conjunto ventilador Quite la rejilla desconecte las luces y el motor saque el tornillo y retire...

Page 8: ...aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as...

Reviews: