MODELS   QTXE110S • QTXE110S2  

TYPICAL INSTALLATIONS

Housing mounted to 

I-joists.

Housing mounted anywhere 

between trusses using hanger 

bars.

PLAN THE INSTALLATION

1.  Choose the 

installation 

location.

The location of 

your humidity 

sensing fan is 

very important. 

Use the follow-

ing guidelines 

for best opera-

tion:

Housing mounted anywhere be-

tween I-joists using hanger bars.

Housing mounted to joists.

Housing mounted anywhere be-

tween joists using hanger bars.

Housing mounted anywhere be-

tween trusses using hanger bars.

INSTALL HOUSING & 
DUCT

1a. Mount 

housing 

to joist 

or I-joist.

 
  Use a pliers to 

bend housing 

TABS

 out to 

90

0

. Hold hous-

ing in place so 

that the hous-

ing tabs con-

tact the bottom 

of the joist. 

The housing 

mounts with 

four (4) screws 

or nails. Screw 

or nail housing 

to joist through 

lowest holes in 

each mount-

i n g   f l a n g e ,  

then through 

highest holes. 

SPACER

(use for mounting to I-Joist)

TABS

I

-JOIST

NOTE: Mounting to 

I-JOIST

 (shown) requires use of 

SPACERS

 (included) between the highest hole of each 

mounting flange and the I-joist.

OR

•  Locate unit above (GFCI protected circuit required) or 

within 5 feet of shower head.

•  Locate unit away from heating or cooling sources 

which can affect humidity levels.

•  Do not locate near window. Unit may respond to the 

outdoor humidity level.

•  Unit must be installed in ceiling to properly sense 

moisture.

•  Locate unit only on flat ceilings up to 12 feet high for 

proper sensing.

•  The ducting from this fan to the outside of the building 

has a strong effect on the air flow, noise and energy 

use of the fan. Use the shortest, straightest duct rout-

ing possible for best performance, and avoid installing 

the fan with smaller ducts than recommended. Insula-

tion around the ducts can reduce energy loss and 

inhibit mold growth. Fans installed with existing ducts 
may not achieve their rated airflow.

2.  Plan the wiring.

•  Plan to supply the unit with proper line voltage and  

  appropriate power cable. Power cable should be  

  routed to the switch box first and then to the unit  

  (See “CONNECT WIRING” on page 3).

•  Do not operate this unit with a speed control.    

  Damage to the sensor unit will result.

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

6-IN. ROUND

DUCT*

6-IN.

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

Summary of Contents for QTXE110S

Page 1: ...OL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor OPERATION The humidity control and fan can be op erated separately Use a 1 or 2 function wall control D...

Page 2: ...equired or within 5 feet of shower head Locate unit away from heating or cooling sources which can affect humidity levels Do not locate near window Unit may respond to the outdoor humidity level Unit...

Page 3: ...around hanger bars SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 MOUNTING CHANNEL 2 NAIL 4 BOTTOM EDGE OF FRAMING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper...

Page 4: ...LE 6 Finish ceiling Install ceiling material Cut out around housing 7 Plug in wiring Plug wiring into the proper receptacles 8 Attach grille to housing Squeeze grille springs and insert them into slot...

Page 5: ...umidit et le ventilateur peuvent fonctionner s par ment Utilisez une commande murale une ou deux fonctions N utilisez pas un gradateur pour contr ler l humidit ou l clairage Pour plus de d tails consu...

Page 6: ...I illustr e CALE pour fixation aux solives en I ERGOTS SOLIVE EN I exige l utilisation de CALES incluses entre le trou le plus haut de chaque bride de montage et la solive en I OU Situez l appareil au...

Page 7: ...ONTAGE 2 CLOU 4 BORD INF RIEUR DE LA CHARPENTE 4 Branchement du c blage lectrique Acheminez un fil de 120 VCA jusqu au lieu d installation Fixez le fil la plaque de c blage avec le connecteur appropri...

Page 8: ...lafond Installez le mat riau du plafond Coupez le autour du bo tier 7 Branchez les fils Branchez les fils dans les prises appropri es 8 Fixez la grille au bo tier Pincez les ressorts de la grille set...

Page 9: ...s ni agua en o cerca del sensor OPERACI N Para registrar este producto visite www broan com El control de humedad y el ventilador pueden funcionar separadamente Utilice un control de pared de 1 2 func...

Page 10: ...gido con un GFCI Ubique la unidad lejos de fuentes de calefacci n o enfriamiento que puedan afectar los niveles de humedad No la ponga cerca de una ventana La unidad puede responder a los niveles de h...

Page 11: ...l ctricos Extienda el cableado de la casa de 120 V CA al lugar de la instalaci n Utilice una conexi n aprobada por UL para afianzar el cableado de la casa a la placa de cableado Conecte los cables tal...

Page 12: ...l del cielo raso Recorte alrededor de la cubierta 7 Conecte el cableado Enchufe las conexiones en los recept culos adecuados 8 Acople la rejilla a la cubierta Apriete los resortes de la rejilla e ins...

Reviews: