SERVICE PARTS

99043586C

 Key No.  Part No. 

Description

 

97016466  Housing

 

97016450  Duct Connector-6”

 

98010102  Wiring Plate

 

99170245  Screw, #8-18 X .375

 

97017086  Wire Panel/Harness Assembly *

 

99020284  Blower Wheel

 

99080598  Motor

 

99100491  Isolator (4 req’d)

 

97017083  Motor Plate & Control Assembly *

 

10 

99250959  Washer #8 (4 req’d)

 

11 

99260558  Nut, Hex Lock #8-32 (4 req’d)

 

97017452  Blower Assembly *

 

 

 

  (includes key nos. 6 thru 11)

 

12 

97016965  Grille Assembly *

 

 

 

 

  (includes key nos. 13, 14 & 17)

 

13 

99140199  Grille Spring (2 req’d)

 

14 

99111345 

Lens

 

15 

99111293 

Spacer (2 supplied)

 

16 

SQTHB1 

Hanger Bar Kit

 

17 

99271344  Sensor Wire Harness

 

18 

99420665  Thumbscrew, #8-18 x .375

TAB

INSTALL GRILLE

6.  Finish ceiling.

 

Install ceiling material. Cut out around housing.

7.  Plug in wiring.

 

Plug wiring into the proper receptacles.

8.  Attach grille to 

housing.

 

Squeeze grille springs and 

insert them into slots on 

each side of housing.

10. Remove light lens.

 

Carefully insert a small 

flat-blade screwdriver be

-

tween grille and lens. Pry 

lens out.

9.  Push grille against 

ceiling.

11. Install light bulbs.

 

Purchase an incandescent 

bulb (100W max.) and a 

4W incandescent night-

light bulb and screw them 

into their sockets. Replace 

lens.

WARRANTY

BROAN THREE YEAR LIMITED WARRANTY

Broan warrants to the original consumer purchaser of its products that such products will be free 

from defects in materials or workmanship for a period of three years from the date of original pur-

chase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT 

LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 

PURPOSE.

During this three-year period, Broan will, at its option, repair or replace, without charge, any product 

or part which is found to be defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This 

warranty does not cover (a) normal maintenance and service or (b) any products or parts which have 

been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), 

faulty installation or installation contrary to recommended installation instructions.

The duration of an implied warranty is limited to the three-year period as specified for the express 

warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above 

limitation may not apply to you.

BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE 

PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL 

NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT 

OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow 

the exclusion or limitation of incidental or consequential damages, so the above limitation may not 

apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which vary from 

state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated 

below, (b) give the model number and part identification and (c) describe the nature of any defect 

in the product or part. At the time of requesting warranty service, you must present evidence of the 

original purchase date.

Broan-NuTone LLC    Hartford, Wisconsin    www.broan.com    800-558-1711

SERVICE NOTE

 

To remove Blower Assembly: Unplug motor (7). 

Remove thumbscrew (18)  from motor plate (9) 

flange. Find the single 

TAB

 on the motor plate (lo-

cated next to the receptacle). Push up near motor 

plate tab while pushing out on side of housing. 

Or insert a straight-blade screwdriver into slot in 

housing (next to tab) and twist screwdriver.

* Parts not listed are included with Assembly.

Order service parts by “Part No.” - not by “Key No.”

Replacement parts can be 

ordered on our website. 

Please visit us at 

www.broan.com

Summary of Contents for QTX110SL

Page 1: ...R SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor OPERATION The humidity control fan light and night light can be operated separately Use a 3 or 4 function wall c...

Page 2: ...est holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist OR ROOF CAP 6 in ROUND ELBOW 6 in ROUND DUCT WALL CAP Purchas...

Page 3: ...framing 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wiring to wiring plate Connect wires as shown in wiring diagrams...

Page 4: ...FLUORESCENT LAMP STARTERSAND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance...

Page 5: ...NI POLVOS ABRASIVOS 3 NO USE sprays limpiadores solventes ni agua en o cerca del sensor OPERATION El control de humedad el ventilador la l mpara y la l mpara de noche pueden funcionar sepa radamente U...

Page 6: ...medad No la ponga cerca de una ventana La unidad puede responder a los niveles de humedad del exterior La unidad se debe instalar en el cielo raso para detectar adecuadamente la humedad Ubique la unid...

Page 7: ...para que funcione autom ticamente 1b Instale la cubierta en cualquier parte entre las armaduras viguetas o viguetas I por medio de barras de suspensi n Se proporcionan barras de suspensi n deslizantes...

Page 8: ...BOS DE LAS L MPARAS FLUORES CENTES Esta garant a no cubre a mantenimiento y servicio normales ni b ning n producto o piezas que se hayan sometido a uso inadecuado negligencia accidente mantenimiento o...