background image

Page

MODEL   QTX110HFLT

TYPICAL INSTALLATION

HOUSING

CEILING

JOIST, TRUSS,

OR I-JOISTS

MOUNTING

CHANNELS

GRILLE

CEILING

MATERIAL

POWER

CABLES

Housing mounted directly to joists, trusses, or 

I-joists. 

Up to 4-inches on-center.

PLAN THE INSTALLATION

INSTALLATION

2.  Mount hous-

ing.

 

Secure hous-

ing to ceiling 

structure with (4) 

mounting screws. 

Make sure bottom 

of housing will be 

flush with finished 

ceiling material.

1.  Insert 

mounting 
brackets.

 

Slide the (4) 

mounting brack-

ets into the chan-

nels on each end 

of the housing.

3.  Attach 

damper 
/ duct 
connector 
to housing.

 

Snap damper / 

duct connector 

onto housing. 

Make sure con-

nector is flush 

with top of hous-

ing and damper 

flap falls closed.

4.  Install 6-

inch round 
ductwork.

 

Connect 6-inch 

round ductwork 

to damper / duct 

connector. Run 

ductwork to a 

roof cap or wall 

cap. Tape all 

ductwork con-

nections to make 

them secure and air tight.

The unit will operate most quietly and efficiently when located 

where the shortest possible duct run and minimum number of 

elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce 

backdrafts.
Plan to supply the unit with proper line voltage and appropriate 

power cable.

ROOF

CAP 

*

6-IN. ROUND

ELBOW(S) 

*

6-IN.

ROUND

DUCT 

*

WALL

CAP 

*

*

 Purchase

  separately

INSULATION

(Can be placed 

around and over 

fan housing.)

FAN

HOUSING

Summary of Contents for QTX Series

Page 1: ... the motor bearings are making excessive or unusual noises replace the motor with the exact service motor The impeller should also be replaced Replace light bulbs with 2 18 Watt 3500K maximum GU24 based fluorescent lamps and 1 7 Watt night light bulb OPERATION Use a 4 Function Control to operate the heater fan light and night light separately See Connect Wiring for details BROAN NUTONE THREE YEAR ...

Page 2: ...ng Snap damper duct connector onto housing Make sure con nector is flush with top of hous ing and damper flap falls closed 4 Install 6 inch round ductwork Connect 6 inch round ductwork to damper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork con nections to make them secure and air tight The unit will operate most quietly and efficiently when located where the shortest pos...

Page 3: ...se wiring to wiring plate Connect wires as shown in wiring diagram s CONNECT WIRING INSTALL GRILLE BULBS 7 Remove light lens from grille Insert a small flat bladed screw driver into the slot at one end of the light lens Care fully pry the lens out 6 Finish ceiling Install ceiling material Cut out ceiling material closely around housing GREEN WHITE to WHITE HEAT 2 position rocker LIGHT red NIGHT LI...

Page 4: ...0 4 req 14 99260488 Nut Hex 10 24 5 req 15 97016564 Heater Scroll 16 99020283 Wheel Heater 17 99260423 Nut Hex 8 32 4 req 18 98010088 Motor Mount 19 99080558 Motor Heater 20 97016565 Heating Element includes Key No 7 97016566 Heater Scroll Assembly includes Key Nos 12 thru 20 21 99020284 Wheel Fan 22 99080556 Motor Fan 23 99100491 Isolator 4 req 24 97016471 Partition 25 99250959 Washer 4 req 26 99...

Page 5: ...terior de la unidad con el accesorio del cepillo para sacudir polvo El motor está permanentemente lubricado y nunca necesitará aceite Si los cojinetes del motor están haciendo ruido excesivo o inusual reemplace el motor con el motor de servicio exacto El impulsor también debe ser reemplazado Reemplace las lámparas con dos 2 lámparas fluorescentes de 18 watts 3500K máximo base de GU24 y un 1 foco d...

Page 6: ...n la cubierta Asegúrese de que el conector esté al ras con la parte superior de la cubierta y que la aleta del regulador caiga cerrada 4 Instale el conducto redondo de 6 pulg Conecte el con ducto redondo de 6 pulg al conec tor del regulador conducto Ex tienda el conducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas y hacerlas herméticas al air...

Page 7: ...ado Conecte los cables tal como se ilustra en los diagramas de cableado CONEXIÓN ELÉCTRICA INSTALE LA REJILLA Y LOS FOCOS 7 Quite la lente del foco de la rejilla Inserte un pequeño destornillador plano en la rejilla en un extremo de la lente del foco Haga palanca con cuidado para retirar la lente 6 Termine el cielo raso Instale el material del cielo raso Recorte el material del cielo raso de cerca...

Page 8: ...gonal 10 24 se req 5 15 97016564 Desplazador del calefactor 16 99020283 Disco Calefactor 17 99260423 Tuerca hexagonal 8 32 se req 4 18 98010088 Montaje del motor 19 99080558 Motor Calefactor 20 97016565 Elemento de calefacción incluye clave no 7 97016566 Conjunto del desplazador del calefactor incluye clave nos 12 á 20 21 99020284 Disco Ventilador 22 99080556 Motor Ventilador 23 99100491 Aislante ...