background image

Page 1

MODEL QTRE080C2S

WARNING

 

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. If you 

have questions, contact the manufacturer at the address or telephone 
number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel and 

lock the service disconnecting means to prevent power from being 
switched on accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent warning device, such 
as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by  qualified personnel 

in accordance with all applicable codes and standards,including 
fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting of gases 

through the flue (chimney) of fuel burning equipment to prevent 
backdrafting. Follow the heating equipment manufacturer’s guideline 
and safety standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local 
code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.

7.  Acceptable for use over a tub or shower when connected to a GFCI 

(Ground Fault Circuit Interrupter) - protected branch circuit (ceiling 
installation only).

8.  To reduce the risk of fire or electric shock, do not use this fan with any 

solid state speed control device.

9.  This unit must be grounded.

10. When applicable local regulations comprise more restrictive installation 

and/or certification requirements, the aforementioned requirements 
prevail on those of this document and the installer agrees to conform 
to these at his own expenses.

11. When performing installation, servicing or cleaning this unit, it is 

recommended to wear safety glasses and gloves.

CAUTION

 

!

1.  For general ventilating use only. Do not use to exhaust hazardous

or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

3.  Please read specification label on product for further information and 

requirements.

SELECT-AIR
VENTILATION FAN

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

WARRANTY

BROAN 

THREE-YEAR LIMITED WARRANTY

Broan warrants to the original consumer purchaser of its products that such 
products will be free from defects in materials or workmanship for a period of 
three (3) years from the date of original purchase. THERE ARE NO OTHER 
WARRANTIES,  EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, 
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE.

During this three-year period, Broan will, at its option, repair or replace, without charge, 
any product or part which is found to be defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR 
TUBES, BULBS OR BATTERIES, FILTERS, DUST, ROOF CAPS, WALL CAPS AND 
OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal 
maintenance and service or (b) any products or parts which have been subject to 
misuse, negligence, accident, improper maintenance or repair (other than by Broan), 
faulty installation or installation contrary to recommended installation instructions.

The duration of an implied warranty is limited to the three-year period as specified 
for the express warranty. Some states do not allow limitation on how long an implied 
warranty lasts, so the above limitation may not apply to you.

BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL 
BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. 
BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL 
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR 
PERFORMANCE.  Some states do not allow the exclusion or limitation of incidental 
or consequential damages, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which 
vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan at the address or telephone number 
stated below, (b) give the model number and part identification and (c) describe the 
nature of any defect in the product or part. At the time of requesting warranty service, 
you must present evidence of the original purchase date.

Date of Installation 

 

Builder or Installer

Model Number and Product Description

IF YOU NEED ASSISTANCE OR SERVICE:

For U.S. customers:

 Broan-NuTone LLC   Hartford, Wisconsin

www.broan.com                     800-558-1711

For canadian customers:

 Broan-NuTone Canada Inc.

1140 Tristar Drive, Mississauga, Ontario L5T 1H9

www.broan.ca                         888-882-7626 

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive appearance - 
lower or remove grille and vacuum interior of unit with the dusting brush 
attachment.

The motor is permanently lubricated and never needs oiling. If the motor 
bearings are making excessive or unusual noises, replace the blower 
asssembly (includes motor and impeller).

OPERATION

BB0001

Canadian customer, 

register your product 

online at www.broan.ca

This ventilator can be operated using either a two-function wall control 
(ON/OFF and High/Low speed) or, for continuous low speed with boost 
to high speed operation, a standard single function wall control; controls 
to be purchased separately. See “Connect Wiring” for details.

Released April 2011

U.S. customer, 

register your product online 

at www.broan.com

30042446A

Summary of Contents for QTRE080C2S

Page 1: ...TO IMPLIEDWARRANTIES OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE During this three year period Broan will at its option repair or replace without charge any product or part which is found t...

Page 2: ...ROOF CAP 4 IN ROUND ELBOW S 4 IN ROUND DUCT WALL CAP Purchase separately INSULATION Can be placed around and over fan housing FAN HOUSING INSTALL HOUSING DUCT BD0001 1a Mount housing to joist or I jo...

Page 3: ...ER BAR 4 SCREWS 4 TAB MOUNTING CHANNEL 2 3 Install 4 inch round duct work Connect 4 inch round ductwork to damper duct connector Run ductwork to a roof cap or wall cap Tape all ductwork connections to...

Page 4: ...102 Wiring Plate 4 99170245 Screw no 8 18 x 375 5 10941351 Wire Panel Harness Assembly 6 10941352 Blower Assembly QTRE080C2S 7 97016497 Grille Assembly incl key no 8 8 99140199 Grille Spring 2 req d 9...

Page 5: ...NTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTICULIER Pendant cette p riode de trois ans Broan son choix r parera ou remplacera gratuitement tout produit ou pi ce qui...

Page 6: ...RILLE BO TIER MAT RIAU DE PLAFOND C BLE LECTRIQUE BRIDES DE MONTAGE SOLIVE DE PLAFOND C BLE LECTRIQUE BO TIER MAT RIAU DE PLAFOND GRILLE SOLIVE DE PLAFOND BARRES DE SUSPENSION s tirent jusqu 24 po MAT...

Page 7: ...toit ou de mur Sceller herm tiquement touslesjoints l aide de ruban conduits TROU POUR VIS DE MONTAGE OPTIONNELLE 4 VIS 2 INSTALLATION DU BO TIER ET DU CONDUIT SUITE BRANCHEMENT LECTRIQUE Commande dou...

Page 8: ...TTE Rep re n Pi ce n Description 1 97016466 Bo tier 2 97016449 Raccord de conduit 4 po 3 98010102 Plaque de branchement 4 99170245 Vis n 8 18 x 0 375 po 5 10941351 Panneau de branchement harnais 6 109...

Page 9: ...s 3 a os a partir de la fecha de la compra original NO EXISTEN OTRAS GARANT AS EXPL CITAS O IMPL CITAS INCLUYENDO ENTRE OTRAS GARANT AS IMPL CITAS DE COMERCIALIZACI N O APTITUD PARA UN PROP SITO PARTI...

Page 10: ...ELO RASO LEG ETAS DE MONTAJE VIGUETA DE CIELO RASO REJILLA CUBIERTA CABLE EL CTRICO MATERIAL DEL CIELO RASO BARRAS DE SUSPENSI N se extienden hasta 24 pulg VIGUETA DE CIELO RASO REJILLA CUBIERTA CABLE...

Page 11: ...ondo de 4 pulg al conector del regulador conducto Extiendaelconducto hacia una tapa de techo o tapa de pared Encinte todas las conexiones de los conductos para fijarlas y hacerlas herm ticas al aire O...

Page 12: ...lave n Pieza n Descripci n 1 97016466 Cubierta 2 97016449 Conector de conductor 4 pulg 3 98010102 Placa de cableado 4 99170245 Tornillo 8 18 x 0 375 pulg 5 10941351 Conjunto del panel de cableado arn...

Reviews: