INST
ALLA
TION,
USE & CARE INSTR
UCTIONS
INST
ALLA
TION
6
CONNECT DUCTWORK
Ducted Installation
Use 7” round metal duct to connect the discharge collar
on the power module to the ductwork above. An optional
7” round damper, model BP87Q, may be used (purchase
separately).
NOTE: Due to its design, the BP87Q 7” round damper
cannot be installed directly over the power module
discharge collar; if this damper has to be installed,
it must be attached between two sections of
7” round metal duct (Fig. 11). Use metal foil tape
to make all joints secure and air tight.
Non-Ducted Installation
The 358NDK non-duct kit is required for this type of
installation (purchase separately). To install, follow the
intructions packed with this kit.
WIRING
WARNING
Risk of electric shock. Electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards. Before connecting
wires, switch power off at service panel and lock
service disconnecting means to prevent power from
being switched on accidentally.
1. Using appropriate wire nuts (not included), connect house
power cable to power module wiring: BLACK to BLACK,
WHITE to both WHITE wires and GREEN or bare wire to
GREEN ground wire (Fig. 12).
2. Reinstall the electrical cover in the power module using its
both retaining screws.
CAUTION
Take care not to pinch wires while reinstalling wiring
cover.
INSTALL THE FILTER
Ducted Installation
Reinstall the grease filter.
Non-Ducted Installation
Attach the non-ducted filter (included with the 358NDK
non-duct kit) to the back of the grease filter using clips
(provided with non-ducted filter). To order a new non-
ducted filter, use service part number S99010464.
!
DUCTED
INSTALLATION
ONLY
BP87Q
7" ROUND DUCT
SECTION
FIG. 11
FIG. 12
2 WHITE WIRES
BLACK WIRE
GREEN
GROUND
WIRE
HOUSE
POWER
CABLE