9. Finish ceiling, remove mask, 

then install grille.

Remove mask from housing. Squeeze grille springs 

and insert into slots in housing.

7.  Install blower.

Re-install blower. Secure blower with 2 screws from parts 

bag and plug blower into black receptacle. Plug in humidity-

sensing control.

3.  Remove old fan.

Enlarge ceiling opening (if necessary) to 9¾-inches 

(parallel to joist) by 10½-inches (perpendicular to joist). 

Leave ductwork and wiring in place.

1

2

4.  Fold mounting ears flat against 

housing.

RETROFIT

 CAUTION

•  Make sure that the wiring inside of 

the housing does not interfere with 

re-installation of the blower.

8. Install housing mask.

Place mask into housing 

opening to 

prevent drywall 

spray and 

construction dust 

from damaging 

blower.

Push grille up against ceiling.

Leav

e this mask in place t

o pre

vent 

constr

uction dust, dr

ywall spr

ay, or paint

 

from damaging inside of pr

oduct.

 

REMO

VE MA

SK BEFORE 

INST

ALLING GRILLE.

Laissez ce masque en place pour empêcher 

la poussièr

e de constr

uction, le plâtr

e ou la 

peintur

e, etc.

 d’endommager

 

l’intér

ieur du pr

oduit.

 

ENLEVEZ CE MA

SQUE 

AVANT

 

D’INS

TALLER LA GRILLE.

Deje est

a cubier

ta en su lug

ar par

a evit

ar 

que pol

vos de constr

ucción, r

ocíos de y

eso 

o pintur

a dañen el int

erior del pr

oduct

o. 

QUITE LA CUBIER

TA ANTES 

DE INS

TALAR LA REJILLA.

99352432A

Summary of Contents for InVent AE110S

Page 1: ...Humidity Sensing Fan Ventilador con sensor de humedad AE80S AE110S Model numbers N meros de modelo INSTALLATION AND USE CARE INSTRUCTIONS INSTRUCCIONES PARA INSTALACI N Y USO Y CUIDADO English See pag...

Page 2: ...PA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring...

Page 3: ...back ON and fan will turn ON 50 60 80 70 10 5 60 15 40 20 30 50 HUMIDITY MINUTES HUMIDITY ADJUSTMENT HUMIDITY has been factory set at 80 for most shower applications If fan is not responding to changi...

Page 4: ...ing POWER CABLE Purchase separately OR Keep duct runs short 4 IN ROUND DUCT ALL INSTALLATIONS Start here IMPORTANT The ducting from this fan to the outside of the building has a strong effect on the a...

Page 5: ...ector to fan housing Push connector through opening from inside of housing Engage tabs and secure with screw from parts bag 4 Mount housing to ceiling structure TABS Make sure bottom of housing will b...

Page 6: ...re that the wiring inside of the housing does not interfere with re installation of the blower 8 Install housing mask Place mask into housing opening to prevent drywall spray and construction dust fro...

Page 7: ...connector Push connector ducting back through opening Engage tabs and secure with screw from parts bag 1 2 3 Install blower Finish ceiling then install grille See Steps 7 8 9 on Page 6 Step 8 is only...

Page 8: ...019514 Housing 2 97019561 97020122 Duct Connector 4 in AE80S Duct Connector 4 in AE110S 3 97020536 Wire Panel Assembly 4 97020538 Humidity Control Panel Assembly 5 97019785 97019786 Blower Assembly AE...

Page 9: ...FPA la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades normativas...

Page 10: ...que se energice el ventilador de esta manera se mantendr prendido durante el periodo establecido en el temporizador Para energizar manualmente el ventilador 1 Si el interruptor de alimentaci n ya est...

Page 11: ...del ventilador CABLE EL CTRICO Se compra por separado O Mantenga cortos los tramos de conductos CONDUCTO REDONDO DE 4 PULG 10 CM TODAS LAS INSTALACIONES Comience aqu IMPORTANTE Los conductos desde es...

Page 12: ...a trav s de la abertura desde el interior de la cubierta Enganche las leng etas y f jelas con los tornillos de la bolsa de piezas 4 Monte la cubierta en la estructura del cielo raso Aseg rese de que l...

Page 13: ...montaje planas contra la cubierta CONVERSI N PRECAUCI N Aseg rese de que el cableado dentro de la cubierta no interfiera con la reinstalaci n del soplador 8 Instale la tapa de la cubierta Coloque la...

Page 14: ...r conducto de vuelta a trav s de la abertura Enganche las leng etas y f jelas con los tornillos de la bolsa de piezas 1 2 3 Instale el soplador Termine el cielo raso y a continuaci n instale la rejill...

Page 15: ...97019514 Cubierta 2 97019561 97020122 Conector de conducto 4 pulg 10 cm AE80S Conector de conducto 4 pulg 10 cm AE110S 3 97020536 Conjunto del panel de cableado 4 97020538 Conjunto del panel de contr...

Page 16: ...e presentar una copia de la garant a limitada original por escrito entonces regir n los t rminos de la garant a limitada por escrito m s actualizada de la compa a para su producto en particular Las ga...

Reviews: