- 3 -
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSON(S) OBSERVE THE FOLLOWING:
1.
This unit is intented for residential installation only.
2.
Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer at the address or telephone number listed
in the warranty.
3.
Before replacing filters, servicing or cleaning unit, disconnect power cord from
electrical outlet.
4.
Installation must be done in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
5.
This unit is not designed to provide combustion and/or dilution air for fuel-burning
appliances.
6.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
7.
Do not use this unit with any solid-state speed control device other than
optional wall controls C12, CM, C34 and CMR (sold separately).
8.
This unit must be grounded. The power supply cord has a 3-prong grounding
plug for your personal safety. It must be plugged into a mating 3-prong grounding
receptacle, grounded in accordance with the national electrical code and local
codes and ordinances. Do not remove the ground prong. Do not use an
extension cord.
9.
Do not install in a cooking area or connect directly to any appliances.
10
. Do not use to exhaust hazardous or explosive materials and vapors.
CAUTION
1.
To avoid prematurate clogged filters, turn OFF the unit during construction or
renovation.
2.
Please read specification label on product for further information and requirements.
3. For HEPA 2000, HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000 units only:
Be
sure to duct air outside – Do not intake / exhaust air into spaces within walls
or ceiling or into attics, crawl spaces, or garage.
4.
Itended for residential installation only in accordance with the requirements of
NFPA 90B.
5.
Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace
or its supply plenum, boiler, or other heat producing appliance.
For HEPA 2000,
HF 2.0, HEPA 3000, HF 3.0 and HEPA 4000 units only,
if a duct has to be
connected to the furnace return plenum, it must be connected not closer than
9’10” (3 m) from this plenum connection to the furnace. For
HEPA 1000 and
HF 1.0 units only,
the distance must be not closer than 2’ (0.61 m).
6.
The ductwork is intended to be installed in compliance with all local and
national codes that are applicable.
WARNING
ABOUT THESE UNITS