WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If

you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a quali-

fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage elec-

trical wiring and other hidden utilities.

FAN/LIGHT
COMBINATION VENTILATORS

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

Homeowner: Use and Care information on page 4.

WARNING

6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked

as appropriate for the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit.

8. Never place a switch where it can be reached from a tub or

shower.

9. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. This product is designed for ceiling installation only. This product

is designed for installation in ceilings up to a 12/12 pitch. Ductwork
must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc. off power
unit.

4. Please read specification label on product for further informa-

tion and requirements.

TYPICAL INSTALLATIONS

TYPICAL INSTALLATIONS

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

16”-ON-CENTER CEILING JOISTS

Housing mounted directly to joist.

24”-ON-CENTER CEILING JOISTS

Housing mounted to additional framing.

Summary of Contents for HD50L

Page 1: ...ing do not damage elec trical wiring and other hidden utilities FAN LIGHT COMBINATION VENTILATORS READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with the homeowner Homeowner Use and Care...

Page 2: ...e proper position for that ceiling material thickness Additional positioning feature for 1 2 thick ceiling material Bend two tabs on side of housing 900 outward Lift housing until tabs contact undersi...

Page 3: ...housing Make sure that tabs on the connector lock into slots in housing Top of damper duct connector should be flush with top of hous ing 2 Connect 4 round duct to damper duct connector and ex tend du...

Page 4: ...isuse negligence accident improper maintenance or repair other thanbyBroan NuTone faultyinstallationorinstallationcontrarytorecommendedinstallationinstruc tions The duration of any implied warranty is...

Page 5: ...eje este manual con el due o de la casa Al due o de la casa Las instrucciones de operaci n y limpieza se encuentran en la p gina 8 5 Cuando corte o perfore la pared o el cielo raso tenga cuidado de no...

Page 6: ...le utilice un tramo de conductos lo m s corto posible y un n mero m nimo de codos 5 8 1 1 1 4 ALETA OROFICIOS BORDE INFERIOR DE LA VIGUETA 3 Coloque la cubierta a un lado y haga una abertura en el tec...

Page 7: ...aci n est terminada estar abierta aproximadamente 1 2 5 cm cuando el conector del conducto se sujete a la cubierta Este dise o permite que el material de aislamiento est en contacto directo con la cub...

Page 8: ...ando como referencia el No DE PIEZA no el No DE CLAVE MODELOS INSTRUCCIONES DE OPERACI N Y LIMPIEZA GARANTIABROAN NUTONE LIMITADAPOR UN A O Broan NuTone garantiza al consumidor comprador original de s...

Reviews: