background image

MODELS  QP430SS • QP436SS • QP442SS

Page 4

MAKE-UP AIR DAMPER

The hood is compatible with Broan Make-Up Air Damper Model 

MD6T or Model MD8T (optional). Purchase separately.
Make the connection to the Make-Up Air Damper with low voltage 

wiring,  as  shown.  See  Make-Up Air  Damper  instructions  for 

additional information.

LOW-VOLTAGE CONNECTOR

FOR MAKE-UP AIR DAMPER

BACK OF HOOD

120

VAC

24

VAC

DAMPER

MOTOR

RANGE

HOOD

MAKE-UP AIR

DAMPER

LOW-VOLTAGE

WIRES

FUSES

The 

Range Hood Control Board

 contains a 

Main Fuse

 and a 

Light Fuse

 to protect the controls from power surges. If a fuse has 

opened (blown), the green fan setting or light setting indicators will 

not operate properly when the fan or light buttons are pressed, and 

the fan and lights will not turn on.
New fuses can be purchased at your local electronic supply store. 

Use 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge-

type fuses.
To replace a fuse (by qualified person(s):

1.  Disconnect power at service entrance.

2.  Remove filters and bottom pan.

3.  Remove and inspect fuse. If it is not open (blown), additional 

diagnostics are needed.

MAIN

FUSE

RANGE HOOD CONTROL BOARD

LIGHT

FUSE

REMOTE CONTROL

The hood is compatible with Broan RF Remote Control Model 
BCR1 (optional). Purchase separately.

HEAT SENTRY SYSTEM

This  range  hood  is  equipped  with  an  advanced  Heat  Sentry 
system that monitors excessive temperature and automatically 
adjusts the fan to the appropriate setting.

1) 

If  the  fan  is  on

,  the  Heat  Sentry  system  will  increase  the 

fan setting when the temperature is elevated. If the temperature 
continues to rise, the Heat Sentry system will continue to increase 
the fan setting until the temperature is stabilized or reduced. The 
flashing light above the fan button shows the Heat Sentry system 
fan setting. Once the temperature has reduced, the Heat Sentry 
system will change the fan to the original setting.

2) 

If the fan is off

, the Heat Sentry system will automatically turn 

the fan on to its highest speed when the temperature is above 
normal. When the Heat Sentry system is on, the light above the 
high speed fan button will flash on and off. After the temperature 
has lowered to normal, the fan speed will be reduced until the 
temperature has stabilized, then the fan will turn off.

Note: Canadian version does not have this function.

Summary of Contents for EVOLUTION QP430SS

Page 1: ...ng at high heat or when flamb ing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use p...

Page 2: ...urn the boost speed off NOTE This hood utilizes an offset blower design to achieve greater performance and lower sound levels As a result you may notice that cooking impurities are more attracted to o...

Page 3: ...ly CLOCK SETTING Press the button once the hours will begin blinking in the LED screen Use the and buttons to set the appropriate hours for the clock A small indicator will illuminate in the left corn...

Page 4: ...blown additional diagnostics are needed MAIN FUSE RANGE HOOD CONTROL BOARD LIGHT FUSE REMOTE CONTROL The hood is compatible with Broan RF Remote Control Model BCR1 optional Purchase separately HEAT SE...

Page 5: ...HOOD HOOD 1 Determine whether hood will discharge vertically 3 x 14 or 7 Round or horizontally 3 x 14 only For vertical or horizontal discharge run ductwork between the hood location and a roof cap or...

Page 6: ...ter and the 7 round duct plate can be installed up to on either side of the hood center Install the 3 x 14 Damper Duct Connector with the Damper Flap Pivot nearest the Top Back Edge of Hood TOP BACK E...

Page 7: ...l Power Cable Knockout from top or back of hood ELECTRICAL POWER CABLE KNOCKOUT CONNECT THE WIRING HOWTO CHANGE LIGHT BULBS Install 4 Halogen Bulbs included with hood Use 120 V 50 W shielded halogen b...

Page 8: ...ich is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENT BULBS FUSES FILTERS DUCTS ROOF CAPS WALL CAPS AND OT...