Broan Elite RMPE Series Instructions Manual Download Page 2

- 2 -

READ AND SAVE THESE INSTRUCTIONS

 

 WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions,

contact the manufacturer at the address or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and lock service

panel to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a qualified person(s) in accor-

dance with all applicable codes and standards, including fire-rated construction codes
and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases through the flue

(chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer’s guidelines and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other

hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any separate solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high settings. Boilovers cause smoking and

greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes

Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).

C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or

filter.

D. Use proper pan size. Always use cookware appropriate for the size of the surface

element.

 

 WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the

burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will

result.

4. Use an extinguisher ONLY if:

A. You know you have a Class ABC extinguisher and you already know how to operate

it.

B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

!

 INTENDED FOR DOMESTIC COOKING ONLY 

!

Summary of Contents for Elite RMPE Series

Page 1: ...RAN AIS 11 ESPA OL 20 Broan NuTone LLC 926 West State Street Hartford WI 53027 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario L5T 1H9...

Page 2: ...ways be vented to the outdoors 7 Do not use this unit with any separate solid state speed control device 8 To reduce the risk of fire use only metal ductwork 9 This unit must be grounded TO REDUCE THE...

Page 3: ...he motor continues to shut off and restart have the hood serviced 7 For best capture of cooking impurities the bottom of the hood should be a minimum of 24 and a maximum of 30 above the cooking surfac...

Page 4: ...IOR OR IN LINE BLOWER SELECTION CAUTION Either an exterior blower or in line blower may be used with this hood The RMPE hood must be installed with blower models 331H 332H 335 336 HLB3 HLB6 HLB9 or HL...

Page 5: ...few of them as possible Larger ducting may be required for best performance with long duct runs 4 After the Exterior or In Line Blower has been installed connect round metal ductwork and work back tow...

Page 6: ...kness of the panel to which it is going to be anchored 5 Insert the hood in the cabinet and lock it by means of the side spring 6 Use the holes in the casing of the hood to attach it using 4 mounting...

Page 7: ...are not pinched between the cover and box Exterior or In Line blower connection 1 Make electrical connections at the exterior orIn Lineblower seeinstructionsprovided with the exterior or In Line blowe...

Page 8: ...se a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth For stubborn cases use a plastic scouring pad or soft bristle brush together with cleans...

Page 9: ...that will turn on or speed up the blower if it senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to HIGH speed 2 If blower is ON at a lower speed setting it turns...

Page 10: ...BROAN NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNEC TION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitati...

Page 11: ...TION BOX COVER 144 B03292287 WIRE CLAMP 152 B03292200 WIRE CLAMP 165 B03294781 WIRING BOX 165 B03295008 WIRING BOX 165 B03294780 CONTROLS BOX 166 B08086141 WIRING BOARD 166 B08086668 WIRING BOARD 195...

Page 12: ...SERVICE PARTS LISTE PIECES DE RECHANGE LISTA DE PIEZAS DE RECAMBIO MODEL RMPE 04307767...

Reviews: