TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.

  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2.

  Before servicing or cleaning unit, switch power off at service 

panel and lock service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3.

 Installation work and electrical wiring must be done by 

qualified personnel in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4.

  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 
to prevent backdrafting. Follow the heating equipment 
manufacturer’s guidelines and safety standards such as 
those published by the National Fire Protection Association 
(NFPA) and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE) and the local code 
authorities.

5.

  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.

  Ducted fans must always be vented outdoors.

7.

  Do not use this unit with any solid-state speed control device.

8.

  To reduce the risk of fire, use only metal ductwork.

9.

  This unit must be grounded.

10.

 

When applicable, local regulations comprise more 
restrictive installation and/or certification requirements, 
the aforementioned requirements prevail on those of this 
document and the installer agrees to conform to these at his 
own expense.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)

  Never leave surface units unattended at high settings. Boilovers 

cause smoking and greasy spillovers that may ignite. Heat oils 
slowly on low or medium settings.

b)

 Always turn power hood ON when cooking at high heat or 

when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambé).

c)

  Clean ventilating fans frequently. Grease should not be allowed 

to accumulate on fan, filters or in exhaust ducts.

d)

  Use proper pan size. Always use cookware appropriate for the 

size of the surface element.

1.

  For indoor use only.

2.

 For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

3.

  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 
unit.

4.

  Your hood motor has a thermal overload which will automatically 

shut off the motor if it overheats. The motor will restart when it 
cools down. If the motor continues to shut off and restart, have 
the hood serviced.

5.

  The minimum hood distance above cooktop is 24” (30” over a 

gas range). A maximum of 30” above cooktop is recommended 
for best capture of cooking impurities.

6.

  Two installers are recommended because of the large size and 

weight of this unit.

7.

  To reduce the risk of fire and to properly exhaust air, be sure to 

duct air outside — Do not exhaust air into spaces within walls 
or ceiling or into attics, crawl space or garage. 

8.

  Because of the high exhausting capacity of this hood, you 

should make sure enough air is entering the house. Open a 
window close to or in the kitchen.

9.

  To reduce the risk of fire and electrical shock, the Bron Elite 

EW54 Series models should only be installed with their own 
built-in blower.

10. 

When used in recirculation mode, to reduce the risk of fire and 
shock, use only conversion kit model HRKMBLS.

11.

 

Please read specification label on product for further 
information and requirements.

    WARNING

CAUTION

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE 
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE 
THE FOLLOWING*:

1.

  SMOTHER FLAMES with a close-fitting lid, cookie sheet or 

metal tray, then turn off the burner. BE CAREFUL TO PREVENT 
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, 
EVACUATE AND CALL THE FIRE DEPARTMENT.

2.

  NEVER PICK UP A FLAMING PAN — You may be burned.

3.

  DO NOT USE WATER, including wet dishcloths or towels — 

This could cause a violent steam explosion.

4.

  Use an extinguisher ONLY if:

 

A.

 You own a Class ABC extinguisher and you know how to 

operate it.

 

B.

 The fire is small and contained in the area where it started.

 

C.

 The fire department has been called.

 

D.

 You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

    WARNING

Summary of Contents for Elite EW54 Series

Page 1: ...TIC COOKING ONLY INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 13 READ AND SAVE THESE INSTRUCTIONS Broan NuTone LLC Hartford Wisconsin www broan com 1 800 558 1...

Page 2: ...ld not be allowed to accumulate on fan filters or in exhaust ducts d Use proper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventila...

Page 3: ...lue extension model FXE54BLS sold separately Before installation remove and discard the shipping bracket in grey and its retaining screws See illustration on the right HD0937 SCREW LOCATIONS 2 SELECT...

Page 4: ...the range hood by pushing them down 1 and tilting them 2 Set aside the filters Remove both styrofoam pieces and tape from under the blower and discard 3 27 8 C L 9 HK0258A 1415 16 1715 16 30 WIDTH HOO...

Page 5: ...y shipped with the blower mounted for a vertical discharge configuration For a horizontal discharge configuration disassemble the blower from the inner top of the hood see procedure below It will be a...

Page 6: ...there is any doubt as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance...

Page 7: ...acket as a template to mark the position of its screws Drill the 3 screw holes using a 3 16 drill bit Insert the included drywall anchors into the drilled holes 1 per hole Secure the upper flue bracke...

Page 8: ...he shipping tape retaining the lower and upper plenum plates with the 6 round adapter together Carefully align the upper plenum plate central notch with the line traced in step 8 see inset at right an...

Page 9: ...included over the adapter damper on the hood Use metal foil duct tape to seal the joint HJ0153 Stretch the flexible metal duct up to the plenum over the adapter Use metal foil duct tape to seal the jo...

Page 10: ...5 angle Gently slide upper flue inside lower flue louvers end up HO0271 LOWER FLUE REAR NOTCH DUCTED INSTALLATION Remove protective plastic film covering the lower flue only Peel off both corners at t...

Page 11: ...upper flue to its bracket using 2 no 8 x 3 8 screws included See illustration beside NOTE Duct not shown in illustration to ease understanding HO0140 UPPER FLUE MOUNTING BRACKET FRONT VIEW UPPER FLUE...

Page 12: ...used to install and remove light bulbs Press suction cup tool on bulb and rotate counterclockwise to remove bulb or clockwise to install bulbs 1 Align the bulb leads with the small indentations locate...

Page 13: ...this will not affect filter performance This discoloration is not covered by the warranty To minimize or prevent discoloration hand wash filters using a mild detergent BLOWER BUTTON When blower is OF...

Page 14: ...back of control board J1 Transformer J2 Power Motor 5 4 3 2 1 5 4 3 2 1 6 7 Control Board R R BL BL BK W BK BK W R Low BK High W 120 V AC Line Neutral Ground COLOR CODE BK BL BN GRY BLACK BLUE BROWN G...

Page 15: ...condition you must use Broan NuTone LLC genuine replacement parts only Broan NuTone LLC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the appl...

Page 16: ...ion instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some States do not allow limitation on how long an implied warranty lasts...

Page 17: ...U PROPRI TAIRE PROPRI TAIRE DIRECTIVES D UTILISATION ET D ENTRETIEN EN PAGE 13 LIRE ET CONSERVER CES DIRECTIVES S RIE EW54 GUIDE D INSTALLATION Broan NuTone LLC Hartford Wisconsin www broan com 1 800...

Page 18: ...d Utilisez le bon format de casserole Servez vous toujours de casseroles et d ustensiles appropri s selon la dimension de la surface chauffante 1 Pour une utilisation l int rieur seulement 2 Pourusag...

Page 19: ...TYPE D INSTALLATION HAUTEUR DU PLAFOND DISTANCE MINIMALE DE LA HOTTE AU DESSUS DE LA SURFACE DE CUISSON D UNE CUISINI RE LECTRIQUE DISTANCE MINIMALE DE LA HOTTE AU DESSUS DE LA SURFACE DE CUISSON D UN...

Page 20: ...po 1415 16 PO 1715 16 PO HOTTE DE 30 PO HOTTE DE 36 PO 3 po 15 16 po VACUATION VERTICALE VACUATION HORIZONTALE HK0261F 6 PO DIA C L 1415 16 PO 1715 16 PO HOTTE DE 30 PO HOTTE DE 36 PO HD0938 2 1 Pose...

Page 21: ...morc e afin de d gager l ouverture pour l vacuation horizontale voir l illustration ci contre HR0123 4 CHOISIR L OUVERTURE 1 D brancher le ventilateur 2 l aide d une douille 5 16 po ou d un tournevis...

Page 22: ...siste quant savoir si l appareil est correctement reli la terre Ne pas utiliser de rallonge lectrique Si le cordon d alimentation est trop court demandez un lectricien d installer une prise de courant...

Page 23: ...n des vis Percer 3 trous l aide d une m che de 3 16 po Ins rer les douilles expansion fournies avec la hotte dans les trous perc s une pour chaque trou Fixer au mur le support de montage du conduit su...

Page 24: ...plaques sup rieure et inf rieure du pl num ainsi que l adaptateur rond de 6 po Aligner soigneusement l encoche centrale de la plaque de pl num sup rieure avec la ligne trac e l tape 8 voir le m daill...

Page 25: ...ssus l adaptateur volet de la hotte Sceller le joint avec du ruban adh sif de m tal HJ0153 tirer le conduit flexible de m tal jusqu au pl num par dessus l adaptateur Sceller le joint avec du ruban adh...

Page 26: ...s d coratifs inf rieur et sup rieur sont inclus avec la hotte Toutefois pour un plafond de 10 pieds se d faire du conduit d coratif sup rieur et utiliser le conduit sup rieur optionnel pi ce n FXE54BL...

Page 27: ...2 vis n 8 x 3 8 po incluses Voir l illustration ci contre NOTE Conduit de ventilation non montr dans l illustration afin de faciliter la compr hension HO0140 SUPPORT DE MONTAGE DU CONDUIT D CORATIF SU...

Page 28: ...res ferm s ATTENTION La plupart des ampoules culot GU10 DEL offertes sur le march ne sont pas con ues pour tre utilis es dans un environnement de cuisson et par cons quent pourraient ne pas offrir le...

Page 29: ...in de nettoyer l air Cela aidera garder la cuisine plus propre et plus fra che BOUTON DU VENTILATEUR Lorsque le ventilateur est en ARR T appuyer sur ce bouton pour ACTIVER le ventilateur la derni re v...

Page 30: ...ute BLA 120 V CA HE0269F BLE BLA N O R BR G 1 2 3 4 5 6 O Moyenne BLA BLA N N J BLA Interface de l utilisateur connect e J10 l arri re de la carte lectronique Commande prioritaire Carte lectronique Al...

Page 31: ...UR VOLET DE 6 PO ROND 1 1 6 SV08582 VENTILATEUR INTERNE INCLUANT CONDENSATEUR 1 1 7 SV05921 AMPOULE HALOG NE AVEC CRAN 120 V 50 W GU10 2 2 8 SV09983 VENTOUSE 1 1 9 99010355 FILTRE MICROMESH 1 2 2 10 S...

Page 32: ...dur e de toute garantie implicite est limit e une p riode de un an telle qu elle est sp cifi e pour la garantie exprim e Certains tats ne permettent pas de limite de temps sur les garanties implicites...

Page 33: ...ROPIETARIO PROPIETARIO INFORMACI N SOBRE USO Y CUIDADO EN LA P GINA 13 LEA Y GUARDE ESTAS INSTRUCCIONES SERIE EW54 INSTRUCCIONES DE INSTALACI N Broan NuTone LLC Hartford Wisconsin www broan com 1 800...

Page 34: ...o adecuado a las dimensiones de la placa el ctrica o fuego 1 S lo para uso interior 2 S lo para ventilaci n general No lo use para evacuar materias ni vapores peligrosos o explosivos 3 Para evitar da...

Page 35: ...E GAS 8 PIES 24 PULGADAS 30 PULGADAS 9 PIES 28 PULGADAS 30 PULGADAS 10 PIES 28 PULGADAS 30 PULGADAS Los techos de 10 pies requieren la prolongaci n de la chimenea modelo FXE54BLS que se vende por sepa...

Page 36: ...SA HK0258E 3 27 8 C L 9 1415 16 1715 16 ANCHURA DE LA CAMPANA 30 ANCHURA DE LA CAMPANA 36 3 15 16 DESCARGA VERTICAL DESCARGA HORIZONTAL HK0261E 6 DI C L 1415 16 1715 16 ANCHURA DE LA CAMPANA 30 ANCHUR...

Page 37: ...el orificio troquelado de la parte trasera de la campana vea la ilustraci n de al lado HR0123 4 ELIJA LA APERTURA 2 Use una llave de tubo de 5 16 o un destornillador Robertson o Phillips n 2 para quit...

Page 38: ...a a tierra del aparato No utilice el aparato con un cable prolongador Si el cable de alimentaci n es demasiado corto haga que un electricista cualificado instale un enchufe m s cerca del aparato de ac...

Page 39: ...n 8 x 3 4 Aseg rese de que el soporte quede bien apretado contra la pared 367 8 PARTE INFERIOR DE LA CAMPANA 24 POR ENCIMA DE LA SUPERFICIE DE COCCI N 427 8 PARTE INFERIOR DE LA CAMPANA 30 POR ENCIMA...

Page 40: ...placas superior y inferior para la c mara impelente y el adaptador redondo de 6 junto Alinee cuidadosamente la muesca central de la placa superior de la c mara con la l nea trazada anteriormente en l...

Page 41: ...e el adaptador compuerta en la campana Utilice cinta adhesiva met lica para sellar la junta HJ0153 Extienda el conducto m talico flexible hasta la c mara sobre el adaptador Utilice cinta adhesiva met...

Page 42: ...erior Las partes inferior y superior de la chimenea vienen con la campana pero para un techo de 10 pies deseche la parte superior y utilice la prolongaci n opcional de la chimenea no de pieza FXE54BLS...

Page 43: ...r de la chimenea al soporte con 2 tornillos n 8 x 3 8 incluidos NOTA no se muestra el conducto en la ilustraci n para facilitar la comprensi n HO0140 SOPORTE DE MONTAJE DE LA PARTE SUPERIOR DE LA CHIM...

Page 44: ...e hacia arriba y gire en el sentido de las agujas del reloj hasta que quede fija ADVERTENCIA No toque las bombillas cuando est n encendidas o poco despu s de apagarlas Podr a quemarse Para evitar el r...

Page 45: ...mpiar el aire una vez apagada la cocina Esto ayudar a mantener toda la cocina m s limpia y despejada BOT N DEL VENTILADOR Cuando el ventilador est apagado OFF pulse este bot n para encender el ventila...

Page 46: ...69E AZ B NE NA R C G 1 2 3 4 5 6 NA Media B B NE NE AM B Interruptor de anulaci n Interfaz de usuario conectado en J10 en la parte trasera de la placa electr nica Interfaz Placa electr nica Potencia M...

Page 47: ...inosde Broan NuTone LLC nicamente Estas piezas se han dise ado especialmente para cada unidad y se han fabricado conforme a las normas de certificaci n aplicables y un elevado nivel de seguridad El us...

Page 48: ...a impl cita se limita a un periodo de un a o como se indica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la l...

Reviews: