The hood should be mounted to the bottom of a standard wall
cabinet. If the hood must be mounted directly to the wall, secure
the hood to wall studs.
The hood is connected to a 11
0
-12
0
V
AC lighting circuit (15
amp) in the circuit breaker or fuse box.
• Ductwork can be installed vertically or horizontally.
• Duct runs should be as short as possible.
• Avoid the use of elbows.
• Use duct tape at all joints.
• Do not use duct smaller than the discharge on the hood.
PLAN THE INSTALLATION
1” TYP.
1” TYP.
9½” TYP.
1” TYP.
2”
12”
6” DIA.
C
L
5½”
10¼”
1” TYP.
1” TYP.
9½” TYP.
1” TYP.
2”
12”
C
L
2¼”
3¼”
12”
2”
¾”
10¼”
3¼”
C
L
HH0055
1. Use the dimensional drawings below to lay out the range
hood’s mounting holes, wiring access and ductwork by
marking the cabinet bottom and drywall where applicable.
2. Make cutouts for wiring and ductwork.
3. Install the ductwork so that it is flush to the range hood’s
mounting surface.
4. Run two-conductor wire (with ground) from a power source
to the hood location. Bring approximately 12” of wiring
through wiring hole.
5. Drill four
3
⁄
32
” diameter pilot holes at points where mounting
holes are marked in cabinet bottom.
6. Insert (4) mounting screws, leaving approximately
1
⁄
4
” of
thread exposed.
LOCATION PREPARATION
VERTICAL DISCHARGE USING 6” ROUND DUCT
VERTICAL DISCHARGE USING 3
1
⁄
4
” X 10” DUCT
HORIZONTAL DISCHARGE USING 3
1
⁄
4
” X 10” DUCT
CUTOUT DIMENSIONS
CABINET TOP VIEW
CABINET BOTTOM VIEW
CUTOUT DIMENSIONS
CABINET TOP VIEW
CUTOUT DIMENSIONS
ROOF CAP
ROOF CAP
EAVES
CAP
WALL
CAP
WALL CAP
ADJUSTABLE
ELBOW
ADJUSTABLE
ELBOW
SUPPLIED
ADAPTER
WALL
CAP
SUPPLIED
ADAPTER
SUPPLIED
ADAPTER/DAMPER
(INSIDE THE HOOD)
-2-