background image

®

Page 8

ALLURE

® 

QS3 SERIES

RANGE HOOD

Página 8

CAMPANA EXTRACTORA

SERIE QS3 ALLURE

®

TORNILLOS PARA EL MONTAJE DE LA CAMPANA (4)

12.7 cm

35.4 cm 

(campana de 76.2 cm)

43.0 cm 

(campana de 91.4 cm)

50.6 cm 

(campana de 106.7 cm)

35.4 cm 

(campana de 76.2 cm)

43.0 cm 

(campana de 91.4 cm)

50.6 cm 

(campana de 106.7 cm)

19.1 cm

FONDO DEL GABINETE

13.3 cm

13.3 cm

CUÑAS DE MADERA

(sólo gabinetes de

fondo empotrado)

3.2 cm

LÍNEA

CENTRAL

5 cm

ORIFICIO DE ACCESO PARA

LOS CABLES ELÉCTRICOS

(en el fondo del gabinete)

26.7 cm

3.8 cm

FRENTE DEL GABINETE

ORIFICIO DE ACCESO

DEL CONDUCTO HORIZONTAL

PLAFÓN

GABINETE

TAPA DE PARED

TAPA DE TECHO

CAMPANA

CAMPANA

CONDUCTO DE

8.3 cm x 25.4 cm O

REDONDO DE 17.8 cm

(para descarga vertical)

CABLEADO ELÉCTRICO

DOMÉSTICO (Parte superior

o posterior de la campana)

CONDUCTO DE
8.3 cm x 25.4 cm
(para descarga
horizontal)

De 45.7 cm a 60.9 cm
SOBRE LA SUPERFICIE
PARA COCINAR

PREPARACIÓN DEL LUGAR DONDE
SE VA A INSTALAR LA CAMPANA

PREPARACIÓN DE LA CAMPANA

1

Quite la 

placa del conducto redondo de 17.8 cm (7”)

 de la

parte superior de la campana. Colóquela aparte, con los tornil-
los de montaje.

2

Quite la cinta que sujeta los 

filtros

 en su lugar. Hale hacia abajo

sujetando las aletas del filtro o las cavidades para los dedos y
saque los filtros. Coloque los filtros a un lado.

PLACA DEL CONDUCTO

REDONDO DE 17.8 CM (7”)

FILTROS

1

Determine si la descarga de la campana va a ser vertical
[conducto de 8.3 cm x 25.4 cm (3 ¼” x 10”) o conducto redondo
de 17.8 cm (7”)], horizontal [sólo conducto de 8.3 cm x 25.4 cm
(3 ¼” x 10”)] o si es un sistema sin conductos. En el caso de
descarga vertical u horizontal, tienda los conductos entre el lugar
donde va a instalar la campana y la tapa de techo o la tapa de
pared. Para obtener los mejores resultados, utilice el número
mínimo de transiciones y codos.

2

Utilice los siguientes diagramas para colocar adecuadamente
los conductos y hacer el corte exacto para la conexión eléctrica
en el gabinete o en la pared. En el caso de aquellas instalaciones
en sistemas sin conductos, NO haga ningún orificio de acceso
para el conducto.

3

Haga las conexiones del cableado doméstico entre el panel de
servicio y el lugar donde va a instalar la campana.

SISTEMA VERTICAL DE CONDUCTOS DE 8.3 cm x 25.4 cm (3 ¼” x 10”)

SISTEMA VERTICAL DE CONDUCTOS

REDONDOS DE 17.8 CM (7”)

PREPARACIÓN DEL LUGAR DONDE
SE VA A INSTALAR LA CAMPANA
(continuación)

SISTEMA HORIZONTAL DE CONDUCTOS DE 8.3 cm x 25.4 cm (3 ¼” x 10”)

CUÑAS DE MADERA
(sólo gabinetes de fondo empotrado)

FRENTE DEL GABINETE

FONDO DEL
GABINETE

9.5 cm

.32 cm

1.9 cm

ORIFICIO DE ACCESO DEL

CONDUCTO HORIZONTAL

35.4 cm (campana de 76.2 cm)
43.0 cm (campana de 91.4 cm)
50.6 cm (campana de 106.7 cm)

35.4 cm (campana de 76.2 cm)
43.0 cm (campana de 91.4 cm)
50.6 cm (campana de 106.7 cm)

13.3

cm

13.3

cm 19.1 cm

TORNILLOS PARA
EL MONTAJE DE
LA CAMPANA (4)

LÍNEA

CENTRAL

ORIFICIO DE ACCESO
PARA LOS CABLES
ELÉCTRICOS (en la pared)

Summary of Contents for ALLURE QS3 SERIES

Page 1: ...the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tr...

Page 2: ...ND DUCT PLATE FILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round or horizontally 3 x 10 only For vertical or horizontal discharge run ductwork between the hood loca tion and...

Page 3: ...CTANGULAR DUCT KNOCKOUT Remove for 3 x 10 Vertical for 7 Round Discharge SEMI CIRCULAR DUCT KNOCKOUT Remove for 7 Round Discharge DAMPER DUCT CONNECTOR ELECTRICAL CABLE CLAMP NOTE If hood is to be ins...

Page 4: ...e sure damper Pivot is nearest to Top Back Edge of hood DAMPER DUCT CONNECTOR Vertical discharge position shown TAPE UP TO 1 SIDE TO SIDE ADJUSTMENT PIVOT TOP BACK EDGE 10 Non Ducted Installations Onl...

Page 5: ...light level Press button again to turn lights off To increase light level press the button To reduce light level press the button There are 3 light levels to select Delay Off While fan is running pre...

Page 6: ...ate includes hardware 2 R740013 Damper DuctConnector includeshardware 3 R602017 Screw 8 18 x Hex 2 in package 4 R334126 Motor Capacitor includes wire nuts hardware 5 R501031 IsolationTransformer 6 R62...

Page 7: ...TADODE UN INCENDIO DEBIDOAGRASAACUMULADAEN LAS HORNILLAS PROCURE LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEM...

Page 8: ...Determine si la descarga de la campana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizontal s lo conducto de 8 3 cm x 25 4 cm 3 x 10 o si es un sistema sin...

Page 9: ...ta con dos tornillos SUJETADORES PLACA CINTA DE METAL TORNILLO CONECTOR DEL REGULADOR DE TIRO CONDUCTO PREPARACI N DE LA CAMPANA continuaci n PREPARACI N DE LA CAMPANA continuaci n 6 Quite el agujero...

Page 10: ...Para reducir el riesgo de descargas el ctricas aseg rese de apagar el interruptor de alimentaci n el ctrica en el panel de servicio Bloquee o rotule el panel de servicio para evitar que alguien conect...

Page 11: ...ldelventiladorfuncionar n adecuadamente cuando se presionen los botones o los conmutadores del ventilador pero ni el ventilador ni las luces se encender n El fusible es de acci n r pida 5 x 20 mm 10 a...

Page 12: ...0 y 21 31 R607660 Tap n 1req 99010308 Juego de filtros para sistemas sin conductos 30 75 cm 99010309 Juego de filtros para sistemas sin conductos 36 90 cm 99010310 Juego de filtros para sistemas sin c...

Reviews: