ALLURE

® 

QS3 SERIES

RANGE HOOD

CABINET
BOTTOM

CABINET FRONT

HORIZONTAL DUCT

ACCESS HOLE

5¼"

5¼"

7½"

1/8

"

¾"

13

15/16

(30" hood)

16

15/16

(36" hood)

13

15/16

(30" hood)

HOOD

MOUNTING

SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in wall)

3¾"

16

15/16

(36" hood)

CENTER

LINE

WOOD SHIMS

(recessed-bottom

cabinets only)

19

15/16

(42" hood)

19

15/16

(42" hood)

SOFFIT

24" - 30" ABOVE
COOKING SURFACE

CABINET

3¼" X 10" DUCT
(For horizontal discharge)

WALL CAP

ROOF CAP

3¼" X 10"  

(For vertical 

discharge)

HOUSE WIRING
(Top or Back of hood)

HOOD

HOOD

HOOD

PREPARE HOOD LOCATION

PREPARE THE HOOD

1

Remove 

7” Round Duct Plate

 from top of hood. Set duct

plate aside - with mounting screws.

2

Remove tape holding 

Filters

 in place. Pull down on filter

tabs or finger holes and lift filters out. Set filters aside.

7” ROUND

DUCT PLATE

FILTERS

1

Determine whether hood will discharge vertically (3¼” x 10”
or 7” Round), or horizontally (3¼” x 10” only). For vertical or
horizontal discharge, run ductwork between the hood loca-
tion and a roof cap or wall cap. For best results, use a mini-
mum number of transitons and elbows.

2

Use diagrams, below, for proper placement of ductwork and
electrical cutout in cabinet or wall. For a non-ducted installa-
tion, DO NOT cut a duct access hole.

3

Run house wiring between service panel and hood location.

VERTICAL DUCT

ACCESS HOLE

1¼"

1½"

10½"

5¼"

5¼"

CENTER

LINE

HOOD MOUNTING SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in cabinet bottom)

WOOD SHIMS

(recessed-bottom

cabinets only)

CABINET FRONT

CABINET BOTTOM

13

15/16

(30" hood)

16

15/16

(36" hood)

7½"

5"

2"

19

15/16

(42" hood)

13

15/16

(30" hood)

16

15/16

(36" hood)

19

15/16

(42" hood)

PREPARE HOOD LOCATION

(Continued)

3¼” X 10”

VERTICAL DUCTING

7” ROUND

VERTICAL DUCTING

3¼” X 10”

HORIZONTAL DUCTING

3¼” x 10”
or 7” round
(For vertical
discharge)

Summary of Contents for ALLURE QS3 SERIES

Page 1: ...the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tr...

Page 2: ...ND DUCT PLATE FILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round or horizontally 3 x 10 only For vertical or horizontal discharge run ductwork between the hood loca tion and...

Page 3: ...CTANGULAR DUCT KNOCKOUT Remove for 3 x 10 Vertical for 7 Round Discharge SEMI CIRCULAR DUCT KNOCKOUT Remove for 7 Round Discharge DAMPER DUCT CONNECTOR ELECTRICAL CABLE CLAMP NOTE If hood is to be ins...

Page 4: ...e sure damper Pivot is nearest to Top Back Edge of hood DAMPER DUCT CONNECTOR Vertical discharge position shown TAPE UP TO 1 SIDE TO SIDE ADJUSTMENT PIVOT TOP BACK EDGE 10 Non Ducted Installations Onl...

Page 5: ...light level Press button again to turn lights off To increase light level press the button To reduce light level press the button There are 3 light levels to select Delay Off While fan is running pre...

Page 6: ...ate includes hardware 2 R740013 Damper DuctConnector includeshardware 3 R602017 Screw 8 18 x Hex 2 in package 4 R334126 Motor Capacitor includes wire nuts hardware 5 R501031 IsolationTransformer 6 R62...

Page 7: ...TADODE UN INCENDIO DEBIDOAGRASAACUMULADAEN LAS HORNILLAS PROCURE LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEM...

Page 8: ...Determine si la descarga de la campana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizontal s lo conducto de 8 3 cm x 25 4 cm 3 x 10 o si es un sistema sin...

Page 9: ...ta con dos tornillos SUJETADORES PLACA CINTA DE METAL TORNILLO CONECTOR DEL REGULADOR DE TIRO CONDUCTO PREPARACI N DE LA CAMPANA continuaci n PREPARACI N DE LA CAMPANA continuaci n 6 Quite el agujero...

Page 10: ...Para reducir el riesgo de descargas el ctricas aseg rese de apagar el interruptor de alimentaci n el ctrica en el panel de servicio Bloquee o rotule el panel de servicio para evitar que alguien conect...

Page 11: ...ldelventiladorfuncionar n adecuadamente cuando se presionen los botones o los conmutadores del ventilador pero ni el ventilador ni las luces se encender n El fusible es de acci n r pida 5 x 20 mm 10 a...

Page 12: ...0 y 21 31 R607660 Tap n 1req 99010308 Juego de filtros para sistemas sin conductos 30 75 cm 99010309 Juego de filtros para sistemas sin conductos 36 90 cm 99010310 Juego de filtros para sistemas sin c...

Reviews: