background image

MODELS   355SOBK • 355SOBR • 355SOWW

Page 1

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, disable the ventilator by cover-

ing the solar panel with cardboard or disconnecting the wires 

from the motor terminals (note wire locations when disconnect-

ing).

3.  Installation work must be done by a qualified person(s) in ac-

cordance with all applicable codes and standards, including 

fire-rated construction codes and standards.

4.  If removing an existing 120 VAC powered attic ventilator, use 

only  a  qualified  person(s)  to  remove  any  electrical  wiring  in 

accordance with all applicable codes and standards.

5.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment manufac-

turer's guidelines and safety standards such as those published 

by  the  National  Fire  Protection Association  (NFPA),  and  the 

American Society for Heating, Refrigeration and Air Condition-

ing Engineers (ASHRAE), and the local code authorities.

6.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  This unit has an unguarded impeller. Do not use in locations 

readily accessible to people or animals.

4.  This ventilator operates when the solar panel is exposed to 

sun light. To reduce risk of injury while installing, servicing or 

cleaning unit, cover the solar panel with cardboard or discon-

nect the wires from the motor terminals (note wire locations 

when disconnecting).

5.  The  recommended  open  air  inlet  for  this  ventilator  is  4.25 

square feet. The best location for these air intake vents are 

under the eaves with direct access to the attic. Failure to pro-

vide these intakes could cause natural-draft gas appliances to 

backdraft.

6.  Your attic fan installation will create a screened opening into 

your attic space. During a heavy rain storm there could be a 

light spray of rain into this attic space. This is a normal condi-

tion with all attic ventilators and will not cause any damage to 

the structure. We recommend that you do not store any valu-

able articles directly under the fan opening in the roof. 

7.  This ventilator is intended for roof installation. Broan Models 

353  &  353SOBK  Gable  Mount  Ventilators  are  available  for 

side wall applications.

8.  The  plastic  ventilator  dome  and  base  may  be  painted  with 

high quality paint. Follow the paint manufacturer's recommen-

dations for acrylic and ABS plastic as appropriate. Take care 

to avoid getting paint on the solar panel.

9.  Please read specification label on product for further informa-

tion and requirements.

10. The  installation  instructions  contained  in  this  document  are 

only  a  recommendation  and  individual  professionals  may 

have  their  own  methods  of  installation.  If  your  roof  has  an 

existing warranty, installation of this product by anyone other 

than those who installed the roof may jeopardize any future 

warranty claim. Please check with the original installer of your 

roof if this is a concern. 

11.  When working with asphalt shingles in cold weather (below 

40

0

 F), take care to avoid damage to the shingle edges and 

corners.

ROOF-MOUNT 

SOLAR POWERED 

ATTIC VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

Drill

1/4" Drill Bit

Sabre Saw or Keyhole Saw

Hammer

Ruler / Tape Measure

Pencil, Marker or Scribe

Utility Knife

Pry Bar (to remove roofing nails)

5/16" Socket and Extension

Roofing Cement

Galvanized Roofing Nails (1¾" min.)

TOOLS AND MATERIALS REQUIRED

Register your product online at:

www.broan.com/register

Summary of Contents for 355SOBK

Page 1: ...con nect the wires from the motor terminals note wire locations when disconnecting 5 The recommended open air inlet for this ventilator is 4 25 square feet The best location for these air intake vents...

Page 2: ...1 Determine the sun s best exposure location on your roof barring shade trees other buildings etc at 4 00pm in the hottest month of the year Generally we recommend a point located 24 36 on center belo...

Page 3: ...ole for the sabre saw just inside of the line or the 14 circle created in Step 8 10 Cut out the roof board s inside of the line 11 For proper removal of roofing nails draw a 26 square centered around...

Page 4: ...tor base is pointed toward the roof ridge start two thirds of the way down from the top of the 26 square and slide the ventilator base under the shingles Do not bend the shingles any more than necessa...

Page 5: ...er Wood 1 S99527247 S99527248 S99527249 Solar Panel Assembly Dome 2 S99527261 S99527261 S99527261 Fan Blade w Set Screw 3 S99527257 S99527257 S99527257 Motor DC 4 S99527250 S99527251 S99527252 Base Ro...

Page 6: ...ovision herein to the contrary this Warranty shall not extend or obligate Broan to take any action with respect to A Products which have been modified altered installed used or operated in a manner wh...

Page 7: ...lors de l installation de l entretien ou du nettoyage de l appareil couvrez le panneau solaire d un carton ou d branchez les fils des bornes du moteur notez leur position en les d branchant 5 L entr e...

Page 8: ...us expos au soleil sur le toit et sans ombre arbres autres b timents etc 16 h dans le mois le plus chaud de l ann e En r gle g n rale nous recommandons un point situ environ 61 91 cm 24 36 po au centr...

Page 9: ...l int rieur de la ligne du cercle de 35 6 cm 14 po trac l tape 8 10 Coupez le ou les panneaux du toit l int rieur de la ligne 11 Pour enlever correctement les clous toiture tracez un carr de 66 cm 26...

Page 10: ...te du toit glissez la base du ventilateur sous les bardeaux des deux tiers sup rieurs du carr de 66 cm 26 po Ne pliez pas les bardeaux plus que n cessaire Centrez la base du ventilateur sur l ouvertu...

Page 11: ...tre site www Broan com Rep re Mod le 355SOBK noir Mod le 355SOBR brun Mod le 355SOWW bois patin Description 1 S99527247 S99527248 S99527249 Ensemble de panneau solaire d me 2 S99527261 S99527261 S9952...

Page 12: ...e saurait obliger Broan prendre des dispositions en ce qui a trait A des produits ayant t modifi s alt r s install s utilis s ou ayant servi d une mani re non recommand e par Broan y compris tout prod...

Page 13: ...cir el riesgo de lesiones mientras instala da servicio o limpia la unidad cubra el panel solar con cart n o desconecte los cables de las terminales del motor tome nota de las ubicaciones de los cables...

Page 14: ...cho con la mejor exposici n al sol y que no tenga sombra de rboles otros edificios etc a las 4 00 p m en el mes m s c lido del a o Por lo general recomendamos un punto situado de 24 a 36 pulg 61 a 91...

Page 15: ...a l nea o del c rculo de 14 pulg 35 6 cm creado en el paso 8 10 Recorte las tablas del techo dentro de la l nea 11 Para poder quitar adecuadamente los clavos del techo dibuje un cuadrado de 26 pulg 66...

Page 16: ...iente del techo inicie en los dos tercios inferiores del cuadrado de 26 pulg 66 cm y deslice la base del ventilador debajo de las tejas No doble las tejas m s de lo necesario Centre la base del ventil...

Page 17: ...is tenos en www Broan com Clave N o Modelo 355SOBK negro Modelo 355SOBR caf Modelo 355SOWW madera curtida Descripci n 1 S99527247 S99527248 S99527249 Conjunto del panel solar domo 2 S99527261 S9952726...

Page 18: ...i n en la presente que se ale otra cosa esta Garant a no se ampliar para Broan ni la obligar a tomar medida alguna con respecto a A Productos que hayan sido modificados alterados instalados usados u o...

Page 19: ...MODELOS 355SOBK 355SOBR 355SOWW P gina 19...

Page 20: ...MODELOS 355SOBK 355SOBR 355SOWW P gina 20 99527232B...

Reviews: