background image

MODELS  345CSOBK • 345CSOWW

Page 1

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 

TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, disable the ventilator by cover-

ing the solar panel with cardboard or disconnecting the wires 

from the motor terminals (note wire locations when disconnect-

ing).

3.  Installation work must be done by a qualified person(s) in ac-

cordance with all applicable codes and standards, including 

fire-rated construction codes and standards.

4.  If removing an existing 120 VAC powered attic ventilator, use 

only a qualified person(s) to remove any electrical wiring in 

accordance with all applicable codes and standards.

5.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment manufac-

turer's guidelines and safety standards such as those published 

by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Condition-

ing Engineers (ASHRAE), and the local code authorities.

6.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  This unit has an unguarded impeller. Do not use in locations 

readily accessible to people or animals.

4.  This ventilator operates when the solar panel is exposed to 

sun light.  To reduce risk of injury while installing, servicing or 

cleaning unit, cover the solar panel with cardboard or discon-

nect the wires from the motor terminals (note wire locations 

when disconnecting).

5.  The recommended open air inlet for this ventilator is 2 square 

feet. The best location for these air intake vents are under the 

eaves with direct access to the attic. Failure to provide these 

intakes could cause natural-draft gas appliances to backdraft.

6.  Your attic fan installation will create a screened opening into 

your attic space. During a heavy rain storm there could be a 

light spray of rain into this attic space. This is a normal condi-

tion with all attic ventilators and will not cause any damage to 

the structure. We recommend that you do not store any valu-

able articles directly under the fan opening in the roof. 

7.  This ventilator is intended for roof installation. Broan Models 

353 345GOBK & 345GOWW Gable Mount Ventilators are 

available for side wall applications.

8.  The plastic ventilator dome and base may be painted with 

high quality paint. Follow the paint manufacturer's recommen-

dations for acrylic and ABS plastic as appropriate.  Take care 

to avoid getting paint on the solar panel.

9.  This ventilator includes a permanently lubricated motor. Do 

not oil or disassemble.

10. The installation instructions contained in this document are 

only a recommendation and individual professionals may 

have their own methods of installation. If your roof has an 

existing warranty, installation of this product by anyone other 

than those who installed the roof may jeopardize any future 

warranty claim. Please check with the original installer of your 

roof if this is a concern. 

11. When working with asphalt shingles in cold weather (below 

40

o

F), take care to avoid damage to the shingle edges and 

corners.

12. For installations in climates where cold weather condensation 

is not a concern, Broan Model CWT45 thermostat is available. 

It disconnects power to the motor when the temperature drops 

below 50

o

F. Power is applied to the motor when the tempera-

ture reaches 61

o

F.

ROOF-MOUNT CURB

SOLAR POWERED 

ATTIC VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

Drill

1/4" Drill Bit

Sabre Saw or Keyhole Saw

Hammer

Ruler / Tape Measure

Pencil, Marker or Scribe

Utility Knife

Pry Bar (to remove roofing nails)

5/16" Socket and Extension

Roofing Cement

Galvanized #10 x 1" Pancake Head Wood Screws

TOOLS AND MATERIALS REQUIRED

Register your product online at:

www.broan.com/register

Summary of Contents for 345CSOBK

Page 1: ...are feet The best location for these air intake vents are under the eaves with direct access to the attic Failure to provide these intakes could cause natural draft gas appliances to backdraft 6 Your...

Page 2: ...year Generally we recommend a point located 24 36 on center below the roof peak and centrally along the ridgeline on the south southwest or west side of the home 2 Prior to installation we recommend...

Page 3: ...ter point use a nail and string to scribe a 14 diameter circle on the black paper or roof decking 6 Taking into consideration the thickness of your chosen flashing material build a 19 x 19 outside dim...

Page 4: ...rials Ensure flashing on top two thirds of curb is installed under adjacent roofing materials 13 Apply a large bead of silicone on the bottom side of ventilator base Make sure the arrow on the ventila...

Page 5: ...1 77001311 77001313 Solar Panel Assembly Dome 2 CWT45 CWT45 Thermostat Optional 3 79020041 79020041 Fan Blade w Set Screw 4 79080082 79080082 Motor DC 5 77001285 77001286 Roof Sheet Panel Curb SERVICE...

Page 6: ...sion herein to the contrary this Warranty shall not extend or obligate Broan to take any action with respect to A Products which have been modified altered installed used or operated in a manner which...

Page 7: ...ir recommand e pour ce ventilateur est de 0 19 m2 2pi2 Lemeilleuremplacementdecesentr esd airestsousles avant toitacc dantdirectementaugrenier N gligerd am nager de telles entr es d air risque d entra...

Page 8: ...En r gle g n rale nous recommandons un point situ environ 61 91 cm 24 36 po au centre en dessous du fa te du toit et centr sur le pan sud sud ouest ou ouest du toit 2 Avant l installation il est conse...

Page 9: ...un cercle de 35 6 cm 14 po de diam tre sur le papier noir ou le panneau du toit 6 En tenant compte de l paisseur du solin utilis fabriquez un cadre de 48 x 48 cm 19 x 19 po dimensions ext rieures l ai...

Page 10: ...us que le solin des deux tiers sup rieurs du cadre est bien gliss sous le rev tement adjacent du toit 13 Appliquez un gros cordon de silicone sur le dessous de la base du ventilateur Assurez vous que...

Page 11: ...nsemble de panneau solaire d me 2 CWT45 CWT45 Thermostat optionnel 3 79020041 79020041 H lice de ventilateur avec vis d arr t 4 79080082 79080082 Moteur CC 5 77001285 77001286 Panneau de toiture cadre...

Page 12: ...e ne saurait obliger Broan prendre des dispositions en ce qui a trait A des produits ayant t modifi s alt r s install s utilis s ou ayant servi d une mani re non recommand e par Broan y compris tout p...

Page 13: ...a entrada de aire abierta recomendada para este ventilador es de 2 pies cuadrados 0 19 metros cuadrados La mejor ubicaci nparaestasventilacionesdeadmisi ndeaireesdebajo de los aleros con acceso direct...

Page 14: ...Por lo general recomendamos un punto situado de 24 a 36 pulg 61 a 91 cm por debajo del punto m s alto del techo y centrado a lo largo de la l nea del reborde sobre el lado sur suroeste u oeste de la...

Page 15: ...m de di metro sobre el papel negro o la cubierta del techo 6 Tomando en cuenta el espesor del material del cubrejuntas que haya elegido forme un bordillo de 19 x 19 pulg 48 x 48 cm dimensiones exterio...

Page 16: ...stalar el cubrejuntas en los dos tercios superiores del bordillo debajo de los materiales del techo adyacentes 13 Aplique un cord n grande de silicona por el lado inferior de la base del ventilador As...

Page 17: ...l panel solar domo 2 CWT45 CWT45 Termostato opcional 3 79020041 79020041 Aspa del ventilador con tornillo de fijaci n 4 79080082 79080082 Motor CC 5 77001285 77001286 Panel en l mina para el techo Bor...

Page 18: ...ici n en la presente que se ale otra cosa esta Garant a no se ampliar para Broan ni la obligar a tomar medida alguna con respecto a A Productos que hayan sido modificados alterados instalados usados u...

Page 19: ...MODELS MOD LES MODELOS 345CSOBK 345CSOWW Page P gina 19...

Page 20: ...MODELS MOD LES MODELOS 345CSOBK 345CSOWW Page P gina 20 79040171D...

Reviews: